Wyrestorm

From HSYCO
Jump to navigation Jump to search

The Wyrestorm MX0606-PP, MX0606-PP, and MX0606-PP modules are matrix switchers that allow any of their HDMI inputs to be routed over distance to any combination of their display outputs via a single UTP cable. The integration with HSYCO can be accomplished via direct control through the RS-232 port on the module.

Communication

Use a DE-9 (often called DB-9) female-male RS-232 straight cable to connect the RS-232 port on the Wyrestorm module to the serial port on HSYCO server.

RS-232 parameters:

Baud rate 9600
Data bits 8
Stop bit 1
Parity none
Flow control none

HSYCO Configuration

Options

ID Default Values Description
gui true true enable support for the UI object, UISET actions and USER commands
false disable UI support
startupevents false true generate IO events also during the driver’s start-up phase
false start generating events only after HSYCO is aligned with the current status of the system
outputs 4 4 | 6 | 8 number of outputs on the module

wyrestorm.ini

The wyrestorm.ini file is an optional configuration file located in the root directory.

Here you can define the names to assign to the inputs so that they will be automatically added in the objects of the UI interface. Add a new line for each name using the format:

<ioserver_id>.in.<n> = <name>

where <ioserver_id> is the ID of the referred I/O server and <n> is the input number.

For instance:

wyr.in.1 = TV
wyr.in.2 = DVD
wyr.in.5 = PC

Datapoints

ID Value R/W Description
connection online R connection established
offline R HSYCO can't connect to the device
<n> <m> R output <n> has input <m> as source
W set input <m> as source for output <n>
next W select the next input number for output <n>
prev W select the previous input number for output <n>

User Interface

Wyrestorm Object

The Wyrestorm object lets you control one output of a Wyrestorm I/O Server.

The object displays the input selected on the addressed output. If an entry is available in wyrestorm.ini for the selected input, then the specified name will be reported, otherwise the object will show the input number. This object is listed in the Project Editor’s new object list only when at least one Wyrestorm I/O Server is defined.

UI Object wyrestorm.png

Parameters

  • server id: the Wyrestorm I/O server ID
  • output: the output number to be addressed
  • position: the object's position. Use the pixels or rows and columns coordinates format
  • CSS style: the CSS style to apply to the inner text (optional)

Syntax

(wyrestorm <server id>; <output>; <position>; <CSS style>)

E.g.

(wyrestorm serverid; 2; x10y20; font-size:50px)

UISET Actions

Release Notes

3.2.0

  • initial version release


WyreStorm is a registered trademarks of WyreStorm Technologies