Difference between revisions of "Inim"
(Created page with "Guardall QX32i, PX80 and PX500 are multi-area security systems. The integration with HSYCO can be accomplished via direct control through the RS-232 port on the panel. Th I/O ...") |
|||
Line 1: | Line 1: | ||
− | + | Inim SmartLiving panels are multi-area intrusion detection systems. The integration with HSYCO can be accomplished via direct control through the RS-232 port on the board. | |
− | |||
[[Category:I/O Server]] | [[Category:I/O Server]] | ||
Line 7: | Line 6: | ||
Employ a female-female RS-232 crossed cable to connect the panel directly to HSYCO or to an Ethernet/RS-232 gateway. | Employ a female-female RS-232 crossed cable to connect the panel directly to HSYCO or to an Ethernet/RS-232 gateway. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
RS-232 parameters: | RS-232 parameters: | ||
{| class="wikitable" | {| class="wikitable" | ||
| '''Baud rate''' | | '''Baud rate''' | ||
− | | | + | | 57600 |
|- | |- | ||
| '''Data bits''' | | '''Data bits''' | ||
Line 32: | Line 24: | ||
| none | | none | ||
|} | |} | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
== HSYCO Configuration == | == HSYCO Configuration == | ||
Line 72: | Line 58: | ||
|logsize | |logsize | ||
− | | | + | |50 |
|n ≥ 0 | |n ≥ 0 | ||
|the number of log lines to display in the UI object | |the number of log lines to display in the UI object | ||
Line 78: | Line 64: | ||
|- | |- | ||
− | | | + | |pollinterval |
− | | | + | |4 |
− | | | + | |n > 0 |
− | + | |the data acquisition interval, in seconds | |
+ | |||
|- | |- | ||
− | |||
− | |||
+ | |rowspan="3"|mod | ||
+ | |rowspan="3"| | ||
+ | |515 | ||
+ | |the panel model to control. This option is required | ||
|- | |- | ||
− | + | |1050 | |
− | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | |10100 |
− | |||
− | |||
|} | |} | ||
− | === | + | === inim.ini === |
The guardall.ini file is a specific configuration file located in the root directory. | The guardall.ini file is a specific configuration file located in the root directory. |
Revision as of 12:38, 23 December 2013
Inim SmartLiving panels are multi-area intrusion detection systems. The integration with HSYCO can be accomplished via direct control through the RS-232 port on the board.
Contents
Communication
Employ a female-female RS-232 crossed cable to connect the panel directly to HSYCO or to an Ethernet/RS-232 gateway.
RS-232 parameters:
Baud rate | 57600 |
Data bits | 8 |
Stop bit | 1 |
Parity | none |
Flow control | none |
HSYCO Configuration
Options
ID | Default | Values | Description |
---|---|---|---|
gui | true | true | enable support for the UI object, UISET actions and USER commands |
false | disable UI support | ||
startupevents | false | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
logsize | 50 | n ≥ 0 | the number of log lines to display in the UI object |
pollinterval | 4 | n > 0 | the data acquisition interval, in seconds |
mod | 515 | the panel model to control. This option is required | |
1050 | |||
10100 |
inim.ini
The guardall.ini file is a specific configuration file located in the root directory. Here you can define the names of the groups so that they will be automatically added to the user interface. Add a new line for each group using this format:
<io_server_id>.group.<n> = <name>
For instance:
guard.group.1 = Kitchen guard.group.2 = Living room
Datapoints
ID | Value | R/W | Description |
---|---|---|---|
connection | online | R | connection established |
offline | R | HSYCO can't connect to the panel | |
armed | 0 | R | all groups are disarmed |
W | disarm all groups | ||
1 | R | the system is (partially) armed | |
W | arm all groups | ||
alarm | 0 | R | the system is not in a alarm state |
1 | R | the system is in a alarm state | |
tamper | 0 | R | the system is not in a tamper state |
1 | R | the system is in a tamper state | |
panel.tamper | 0 | R | the panel is not tampered |
1 | R | the panel is tampered | |
bell.tamper | 0 | R | the bell is not tampered |
1 | R | the bell is tampered | |
low.volts | 0 | R | voltage ok |
1 | R | low voltage detected | |
sounder | 0 | R | the sounder is inactive |
1 | R | the sounder is active | |
audio | 0 | R | the audio signal of the panel is inactive |
1 | R | the audio signal of the panel is active | |
strobe | 0 | R | the strobe is inactive |
1 | R | the strobe is active | |
mains.fail | 0 | R | no mains fail |
1 | R | mains fail | |
power.fail | 0 | R | no power fail |
1 | R | power fail | |
battery.fail | 0 | R | no battery fail |
1 | R | battery fail | |
fuse.1.fault | 0 | R | fuse 1 is working |
1 | R | fuse 1 in fault | |
fuse.2.fault | 0 | R | fuse 2 is working |
1 | R | fuse 2 in fault | |
fuse.3.fault | 0 | R | fuse 3 is working |
1 | R | fuse 3 in fault | |
line.fault | 0 | R | communication line is working |
1 | R | communication line in fault | |
c<n>.name | <text> | R | the name of circuit <n> is set to <text> |
g<n>.name | <text> | R | the name of group <n> is set to <text> |
g<n>.armed | 0 | R | group <n> is disarmed |
W | disarm group <n> | ||
1 | R | group <n> is armed | |
W | arm group <n> | ||
c<n>.alarm | 0 | R | circuit <n> is not in alarm state |
1 | R | circuit <n> is in alarm state | |
c<n>.tamper.alarm | 0 | R | circuit <n> is not in tamper alarm |
1 | R | circuit <n> is in tamper alarm | |
c<n>.open | 0 | R | circuit <n> is closed |
1 | R | circuit <n> is open | |
c<n>.tamper | 0 | R | circuit <n> is not tampered |
1 | R | circuit <n> is tampered | |
c<n>.fault | 0 | R | circuit <n> is working properly |
1 | R | circuit <n> is faulty | |
c<n>.bypassed | 0 | R | circuit <n> is not bypassed |
W | unbypass circuit <n> | ||
1 | R | circuit <n> is bypassed | |
W | bypass circuit <n> | ||
c<n>.isolated | 0 | R | circuit <n> is not isolated |
W | un-isolate circuit <n> | ||
1 | R | circuit <n> is isolated | |
W | isolate circuit <n> | ||
c<n>.soaked | 0 | R | circuit <n> is not soaked |
W | un-soak circuit <n> | ||
1 | R | circuit <n> is soaked | |
W | soak circuit <n> | ||
c<n>.status | <status_values> | R | the status of circuit <n> is set to the reported values |
c<n>.attributes | <attributes_values> | R | the attributes of circuit <n> are set to the reported values |
c<n>.resistance | <value> | R | the measured resistance on circuit <n> is <value> ohm |
>20k | R | the measured resistance on circuit <n> is greater than 20 K-ohm | |
k<n>.tamper | 0 | R | keypad <n> is not tampered |
1 | R | keypad <n> is tampered | |
k<n>.fault | 0 | R | keypad <n> is working properly |
1 | R | keypad <n> is faulty | |
logon.<n> | <user_num> | R | user with number <user_num> logged in from keypad <n> |
error | R | wrong pin entered in keypad <n> | |
system | reset | W | reset alarms |
Circuit status values | |
---|---|
Value | Description |
A | alarm/open |
B | alarm/open and tamper |
E | latched alarm and tamper |
M | marginal clear |
m | marginal alarm |
N | normal |
T | tamper |
L | latched alarm |
F | fault/no answer |
X | Auxiliary alarm |
Circuit attributes values | |
---|---|
Value | Description |
B | bypassed circuit |
I | isolated circuit |
S | soak failed |
T | soaked circuit |
Y | temporarily bypassed circuit |
Q | temporarily isolated circuit |
H | circuit in shunt |
A | existing circuit |
M | multi-alarm |
F | bank reset failed/door forced |
L | locked |
O | open |
Attributes can be combined together, for instance if a circuit is both isolated and bypassed, the attribute value will be “BI”.
User Interface
Guardall Object
The user interface for the Guardall multi-area intrusion detection system:
The Guardall object is listed in the Project Editor’s new object list only when at least one Guardall I/O Server is defined.
Parameters
- server id: the server ID
- position: the object's position. Use the pixels or rows and columns coordinates format
Syntax
(guardall <server id>; <position>)
E.g.
(guardall serverid; x10y20)
UISET Actions
ID | Attribute | Set to | |
---|---|---|---|
log | value | latest security log lines (as many as specified by the 'logsize' option) | |
log0 | value | latest line of the security log when a new entry is added, set back to blank after a short period | |
c<n>.name | value | name assigned to circuit <n> or its number if no name is defined | |
connection.label | visible | true | when datapoint connection = offline |
false | when datapoint connection = online | ||
<datapoint_id>.label.1 | visible | true | when datapoint with ID <datapoint_id> has value '1' |
false | when datapoint with ID <datapoint_id> has value '0' | ||
<datapoint_id>.label.0 | visible | true | when datapoint with ID <datapoint_id> has value '0' |
false | when datapoint with ID <datapoint_id> has value '1' |
USER Commands
Name | Param | Action |
---|---|---|
armed | 0 | disarm all groups |
1 | arm all groups | |
g<n>.armed | 0 | disarm group <n> |
1 | arm group <n> | |
c<n>.bypassed | 0 | unbypass zone <n> |
1 | bypass zone <n> | |
c<n>.isolated | 0 | un-isolate zone <n> |
1 | isolate zone <n> | |
c<n>.soaked | 0 | un-soak zone <n> |
1 | soak zone <n> | |
system | reset | reset alarms |