Difference between revisions of "Tecnoalarm"
(4 intermediate revisions by 2 users not shown) | |||
Line 57: | Line 57: | ||
|false | |false | ||
|disable support of the tecnoalarm Web interface object | |disable support of the tecnoalarm Web interface object | ||
+ | |- | ||
+ | |||
+ | |rowspan="2"|userlogs | ||
+ | |rowspan="2"|false | ||
+ | |true | ||
+ | |generates logs that can be viewed with the userlist object, and can be selected to generate user events | ||
+ | |- | ||
+ | |false | ||
+ | |logs for userlist objects disabled. Normal text logs are generated even when this option is false | ||
|- | |- | ||
Line 565: | Line 574: | ||
== Release Notes == | == Release Notes == | ||
− | === 3. | + | === 3.4.0 === |
*output.N command data point not working | *output.N command data point not working | ||
*fixed a bug that caused HSYCO to crash when the code and/or model mandatory parameters were not defined | *fixed a bug that caused HSYCO to crash when the code and/or model mandatory parameters were not defined | ||
+ | *user codes starting with one or more zeroes didn't work | ||
+ | *fixed a bug that could prevent reading of the zones status of the TP 8-88 panel | ||
=== 3.3.0 === | === 3.3.0 === | ||
Line 575: | Line 586: | ||
*new (tecnoalarm) object | *new (tecnoalarm) object | ||
*new option persistentconnection = <true|false>. If true (default is false) the I/O Server will not periodically disconnect and reconnect (periodic disconnection is used to avoid performance degradation on some firmware versions) | *new option persistentconnection = <true|false>. If true (default is false) the I/O Server will not periodically disconnect and reconnect (periodic disconnection is used to avoid performance degradation on some firmware versions) | ||
+ | *new option userlogs. Used to create (userlist) clickable logs | ||
=== 3.2.1 === | === 3.2.1 === |
Latest revision as of 14:35, 24 February 2015
The Tecnoalarm TP16-256, TP8-64BUS, TP8-96VIDEO, TP8-96GSM, TP16-512GSM and TP8-88 are advanced, multi-area security systems integrated with a variety of wired and wireless sensors.
The TECNO OUT driver in HSYCO supports the integration of more than one TP unit within the same HSYCO interface.
The integration with HSYCO can be accomplished with a TCP/IP network connection.
Contents
HSYCO Configuration
Add a TECNOALARM I/O Server in the I/O Servers section of the Settings and set its parameters:
Communication
- IP Address: the Tecnoalarm panel address
- IP Port: TCP/IP port enabled on the TECNO OUT.
High Availability
- Shutdown when inactive: defaults to true.
The code and model parameters in Options are actually mandatory. The I/O Server cannot start without these parameters.
Options
ID | Default | Values | Description |
---|---|---|---|
code | code | the user code that the driver uses when sending commands to the Tecnoalarm system. It must be a valid user code, or the MASTER code when using the TP8-64BUS | |
model | string | the system’s model. Use one of the following values: TP16-256, TP8-64BUS, TP8-96VIDEO, TP8-96GSM, TP16-512GSM, TP8-88 | |
startupevents | false | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
gui | true | true | enable support of the tecnoalarm Web interface object |
false | disable support of the tecnoalarm Web interface object | ||
userlogs | false | true | generates logs that can be viewed with the userlist object, and can be selected to generate user events |
false | logs for userlist objects disabled. Normal text logs are generated even when this option is false | ||
logsize | 50 | n ≥ 0 | the number of log events shown in the tecnoalarm Web object. Set to 0 to hide the log in the tecnoalarm object |
pass | string | the passphrase used to encrypt the TCP/IP traffic. If the Tecnoalarm system doesn’t support the passphrase, you should omit this parameter | |
polltime | 1000 | n ≥ 0 | the data polling interval, in milliseconds. Shorter time improve the response of the system, but increase the load on the CPU of both HSYCO and the Tecnoalarm system |
Datapoints
ID | Value | R/W | Description |
---|---|---|---|
connection | online | R | connection established |
offline | R | connection failed | |
system.standby | 1 | R | general system stand-by status |
0 | R | reset | |
system.fault | 1 | R | general system fault (low battery or no AC power) |
0 | R | reset | |
system.lowbattery | 1 | R | general low battery fault |
0 | R | reset | |
system.nopower | 1 | R | general no AC power fault |
0 | R | reset | |
system.tamper | 1 | R | general tamper condition (central unit, zones, modules, modules loss of connection) |
0 | R | reset | |
system.radiofault | 1 | R | general radio modules fault |
0 | R | reset | |
system.duress | 1 | R | duress status |
0 | R | reset | |
system.techzone | 1 | R | general technical zones open status |
0 | R | reset | |
system.normal | 1 | R | normal status (AC power ok, battery ok, all zones closed, no tamper) |
0 | R | reset | |
system.maintenance | 1 | R | maintenance mode |
0 | R | reset | |
system.panic | 1 | R | panic alarm |
0 | R | reset | |
system.indoorsiren | 1 | R | general status of indoor sirens |
0 | R | reset | |
system.outdoorsiren | 1 | R | general status of outdoor sirens |
0 | R | reset | |
zone.<n>.excluded | 1 | R | zone <n> disabled |
0 | R | zone <n> enabled | |
zone.<n>.alarm | 1 | R | zone <n> alarm |
0 | R | reset | |
zone.<n>.cablecutstatus | 1 | R | zone <n> cable cut |
0 | R | reset | |
zone.<n>.cablecutalarm | 1 | R | zone <n> cable cut alarm |
0 | R | reset | |
zone.<n>.lowbattery | 1 | R | zone <n> low battery |
0 | R | reset | |
zone.<n>.noradio | 1 | R | zone <n> radio supervision lost |
0 | R | reset | |
zone.<n>.active | 1 | R | zone <n> active |
0 | R | reset | |
zone.<n>.radiolearned | 1 | R | zone <n> radio learned |
0 | R | zone <n> radio not learned | |
zone.<n> | enable | W | sends a zone <n> enable command using default code |
disable | W | sends a zone <n> disable command using default code | |
enable.C | W | sends a zone <n> enable command using code C | |
disable.C | W | sends a zone <n> disable command using code C | |
program.<n>.status | off | R | program <n> reset |
preout | R | program <n> pre out status | |
out | R | program <n> out status | |
armed | R | program <n> armed | |
outpartial | R | program <n> out partial status | |
armedpartial | R | program <n> armed partial | |
endpartial | R | program <n> end of partial | |
program.<n>.prealarm | 1 | R | program <n> pre-alarm |
0 | R | reset | |
program.<n>.alarm | 1 | R | program <n> alarm |
0 | R | reset | |
program.<n>.alarmmemory | 1 | R | program <n> alarm memory |
0 | R | reset | |
program.<n> | arm | W | sends a program <n> arm command using default code |
disarm | W | sends a program <n> disarm command using default code | |
partial | W | sends a program <n> partial arm command using default code | |
full | W | sends a program <n> full arm command using default code | |
arm.<C> | W | sends a program <n> arm command using code <C> | |
disarm.<C> | W | sends a program <n> disarm command using code <C> | |
partial.<C> | W | sends a program <n> partial arm command using code <C> | |
full.<C> | W | sends a program <n> full arm command using code <C> | |
output.<n>.status | 1 | R | output line <n> on |
0 | R | output line <n> off | |
output.<n> | 1 | W | sends an output <n> on command using default code |
on | |||
0 | W | sends an output <n> off command using default code | |
off | |||
1.<C> | W | sends an output <n> on command using code <C> | |
on.<C> | |||
0.<C> | W | sends an output <n> off command using code <C> | |
off.<C> |
User Interface
Tecnoalarm Object
The user interface for the Tecnoalarm multi-area intrusion detection system:
The Tecnoalarm object is listed in the Project Editor’s new object list only when at least one Tecnoalarm I/O Server is defined.
Parameters
- server id: the server ID
- position: the object's position. Use the pixels or rows and columns coordinates format
Syntax
(tecnoalarm <server id>; <position>)
E.g.
(tecnoalarm serverid; x10y20)
UISET Actions
ID | Attribute | Set to | |
---|---|---|---|
connection.label.online | visible | true when the panel is connected to HSYCO, false otherwise | |
connection.label.offline | visible | true when the panel is not connected, false otherwise | |
program.<n>.status.label.off | visible | true when program <n> is off | |
program.<n>.status.label.preout | visible | true when program <n> is in pre out status, false otherwise | |
program.<n>.status.label.out | visible | true when program <n> is in out status, false otherwise | |
program.<n>.status.label.armed | visible | true when program <n> is armed, false otherwise | |
program.<n>.status.label.outpartial | visible | true when program <n> is in out partial status, false otherwise | |
program.<n>.status.label.armedpartial | visible | true when program <n> is partial armed, false otherwise | |
program.<n>.alarm.label | visible | true when program <n> alarm is active, false otherwise | |
zone.<n>.excluded.label | visible | true when zone <n> excluded, false otherwise | |
zone.<n>.alarm.label | visible | true when zone <n> alarm is active, false otherwise | |
zone.<n>.cablecut.label | visible | true when zone <n> cable cut detected (status or alarm), false otherwise | |
zone.<n>.lowbattery.label | visible | true when zone <n> has low battery, false otherwise | |
zone.<n>.noradio.label | visible | true when zone <n> radio supervision lost, false otherwise | |
zone.<n>.active.label | visible | true when zone <n> is active, false otherwise | |
lock.label | visible | true when the system is armed, false otherwise | |
alarm.label | visible | true when the alarm is active, false otherwise | |
tamper.label | visible | true when a tamper alarm is active, false otherwise |
Log Files
A permanent record of all the events shown in the log page is saved in a file called security.log in the logs/YYYY directory for the current year.
This file is never overwritten or deleted by HSYCO.
2014.07.02 17:56:19.188 - tecno - 02/07/10 17:57:29 Activate Remote 6 Monitor 2014.07.02 17:56:22.211 - tecno - 02/07/10 17:57:32 Deactivate Remote 6 Monitor 2014.07.02 17:56:48.174 - tecno - 02/07/10 17:57:58 Access Remote Master Keyboard 2014.07.02 19:00:06.825 - tecno - 02/07/10 19:01:16 Access Remote Master Keyboardd 2014.07.07 17:07:41.871 - tecno - 07/07/10 17:09:31 Activate Remote 6 Monitor 2014.07.07 17:07:43.669 - tecno - 07/07/10 17:09:32 Deactivate Remote 6 Monitor
Other information related to the Tecnoalarm Tecno Out driver are saved in the daily message.log files.
Release Notes
3.4.0
- output.N command data point not working
- fixed a bug that caused HSYCO to crash when the code and/or model mandatory parameters were not defined
- user codes starting with one or more zeroes didn't work
- fixed a bug that could prevent reading of the zones status of the TP 8-88 panel
3.3.0
- added support for TP8-88
- Tecnoalarm Tecno Out driver converted to I/O Server
- Java API write command methods are now obsolete and deprecated, replaced by IO write commands
- new (tecnoalarm) object
- new option persistentconnection = <true|false>. If true (default is false) the I/O Server will not periodically disconnect and reconnect (periodic disconnection is used to avoid performance degradation on some firmware versions)
- new option userlogs. Used to create (userlist) clickable logs
3.2.1
- Tecno Out: workaround to address a performance issue on Tecno Out introduced with firmware 1.2.07
2.0.0
- full integration within HSYCO 2.9.0
1.1.4
- fixed a bug affecting the TCP/IP communication when using a passphrase