Redscan

From HSYCO
Revision as of 11:33, 12 June 2017 by Giampiero (talk | contribs) (Created page with "The OPTEX REDSCAN is a laser scan detector that can detect a moving object's size, speed, and distance with high-reliability. The integration with HSYCO can be accomplished vi...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

The OPTEX REDSCAN is a laser scan detector that can detect a moving object's size, speed, and distance with high-reliability. The integration with HSYCO can be accomplished via direct control through Ethernet connection. The I/O Server complies with the Optex Redscan Protocol v1.71 and has been tested on firmware version 7.3.0.

Redscan Configuration

This driver is developed on INTEGRA central units with firmware 1.15. The ethernet connection is possibile via the interface ETHM-1 PLUS (firmware 2..02) connected with a PIN5/RJ-TTL cable to the central unit. Set the IP address of the central unit with the software DLoadX. The "integration" checkbox has to be activated. The default TCP/IP communication port is 7094. Do not activate the "encrypted communication".

HSYCO Configuration

Add a REDSCAN I/O Server in the I/O Servers section of the Settings and set its parameters:

Communication

  • IP Address: host name or IP address of the panel
  • IP Port: TCP/IP port to use (as configured on the panel)

High Availability

  • Shutdown when inactive: defaults to true.

Options

ID Default Values Description
eventsport 1234 <port_number> port number to which UDP alarm messages are sent by the scanner. Set to 0 to disable alarm events
areaX1 <x> X coordinate of the upper-right corner of the detection area. If not specified the image is not drawn
areaY1 <y> Y coordinate of the upper-right corner of the detection area. If not specified the image is not drawn
areaX2 <x> X coordinate of the lower-left corner of the detection area. If not specified the image is not drawn
areaY2 <y> Y coordinate of the lower-left corner of the detection area. If not specified the image is not drawn
flipx false true the detected objects image is flipped horizontally
false the image not flipped horizontally
flipy false true the detected objects image is flipped vertically
false the image not flipped vertically
bordercolor red <color> color for the border of the circles representing the detected objects
fillcolor white <color> color for the inner part of the circles representing the detected objects
detectioninterval 10 0 ≤ n ≤ 100 interval between detection reports sent by the scanner. 1 = 50ms, 100 = 5sec. Set to 0 to disable detection events

Datapoints

ID Value R/W Description
connection online R connection established
offline R HSYCO can't connect to the panel
armed 0 R all partitions are disarmed
1 R the system is (partially) armed

User Interface

Release Notes

3.6.0

  • initial version release


OPTEX and REDSCAN are registered trademarks of OPTEX INC.