Difference between revisions of "SIGFOX"
(7 intermediate revisions by the same user not shown) | |||
Line 80: | Line 80: | ||
|30000 | |30000 | ||
|1000<n<30000 | |1000<n<30000 | ||
− | |interval (in milliseconds) between two consecutive HTTP calls | + | |interval (in milliseconds) between two consecutive HTTP calls to Sigfox Cloud (only for API) |
|} | |} | ||
Line 88: | Line 88: | ||
==== API ==== | ==== API ==== | ||
− | In order to use Sigfox API you have to create an API user in Sigfox backend (unless you already have an existing one), then use the newly API user credentials to set '''User''' and '''Password''' in SIGFOX I/O Server configuration | + | In order to use Sigfox API you have to create an API user in Sigfox backend (unless you already have an existing one), then use the newly API user credentials to set '''User''' and '''Password''' in SIGFOX I/O Server configuration. |
==== Callbacks ==== | ==== Callbacks ==== | ||
− | In order to use Sigfox callback services you must have a public IP address and you need to configure your router ports to let outside traffic to get into your network. You also have to set '''callbackkey''' option and '''callbackport''' option (if the default 4445 is already in use or if you are using more instances of SIGFOX driver) in SIGFOX I/O Server options. | + | In order to use Sigfox callback services you must have a public IP address and you need to configure your router ports to let outside traffic to get into your network to your Hsyco. You also have to set '''callbackkey''' option and '''callbackport''' option (if the default 4445 is already in use or if you are using more instances of SIGFOX driver) in SIGFOX I/O Server options. |
Every time Sigfox Cloud receive a message from a device it immediately propagates it to your SIGFOX driver, filling all message informations into an URL. Callback messages must be configured in Sigfox backend (you can configure callbacks for each device type associated to your account) choosing channel "URL" and composing the URL in the following format: | Every time Sigfox Cloud receive a message from a device it immediately propagates it to your SIGFOX driver, filling all message informations into an URL. Callback messages must be configured in Sigfox backend (you can configure callbacks for each device type associated to your account) choosing channel "URL" and composing the URL in the following format: | ||
− | <pre>http://< | + | <pre>http://<public_ip_address>:<port>/hsyco/sigfox/<I/O_server_name>?key=<callbackkey>&id={device}&field1={var1}&field2={var2}&field3={var3}...</pre> |
− | <callbackkey> | + | <port> is the public port opened on your router, <callbackkey> corresponds to '''callbackkey''' option of SIGFOX I/O Server. The URL fields "key" and "id" must be always present. The URL fields "field1", "field2", "field3", etc.. are optionals and can be set accordingly to the type of callback you are configuring in Sigfox backend; fields order is irrelevant. URL fields must be separated with '&' character. |
E.g. | E.g. | ||
Line 276: | Line 276: | ||
=== eccoswitch === | === eccoswitch === | ||
− | Below are reported all datapoints generated from incoming messages from '''eccoswitch''' model devices. Those datapoints are in addition to SIGFOX I/O Server standard datapoints | + | Below are reported all datapoints generated from incoming messages from '''eccoswitch''' model devices. Those datapoints are in addition to SIGFOX I/O Server standard datapoints. |
{| class="wikitable" | {| class="wikitable" |
Latest revision as of 08:34, 21 October 2020
Sigfox is a global network operator founded that builds wireless networks to connect low-power objects such as electricity meters and smartwatches, which need to be continuously on and emitting small amounts of data. This driver allows you to communicate with Sigfox Cloud in order to retrieve messages and status updates collected from devices. As reported in the Sigfox backend, each device is grouped into a device type.
Contents
HSYCO Configuration
Add the SIGFOX I/O Server in the I/O Servers section of the Settings and set its parameters:
Authentication
- User: optional API username
- Password: optional API password
Devices list file
At the first run of SIGFOX driver a file named "sigfox-devices_<I/O_Server_name>.ini" will be created . This file can contain a series of line, each line represents informations of a single device and can have the following format:
<device_id>:name=<device_name>,model=<device_model>
<device_id>:model=<device_model>,name=<device_name>
<device_id>:name=<device_name>
<device_id>:model=<device_model>
<device_id>
E.g.
BE1234:name=homesensor,model=eccoswitch
BE1234:model=eccoswitch,name=homesensor
BE1234:name=homesensor
BE1234:model=eccoswitch
BE1234
Device id must be present in each line while name and model are optional. Device identifiers are considered as case insensitive by the SIGFOX I/O Server, so there can't be two identifiers with the same sequence of characters in upper/lower case, e.g. "BE1234" and "be1234" are considered the same.
Options
ID | Default | Values | Description |
---|---|---|---|
startupevents | true | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
acceptunknown | false | true | accept incoming messages from devices whose id isn't specified in sigfox-devices.ini |
false | doesn't accept incoming messages from devices whose id isn't specified in sigfox-devices.ini | ||
callbackport | 4445 | <portNumber> | internal port used to receive incoming callback messages from Sigfox Cloud |
callbackkey | <text> | key used in Sigfox URL callbacks to receive incoming callback messages | |
pollinterval | 30000 | 1000<n<30000 | interval (in milliseconds) between two consecutive HTTP calls to Sigfox Cloud (only for API) |
Device Messages
To retrieve device messages from Sigfox Cloud you can use API and/or callbacks. API are easier to set up but they require to wait for an interval to expire (max 30 seconds) to get every new message sent by devices to Sigfox Cloud. Callbacks are a little bit tricky to set up but they allow to retrieve every new message sent by devices as soon as Sigfox Cloud receives it.
API
In order to use Sigfox API you have to create an API user in Sigfox backend (unless you already have an existing one), then use the newly API user credentials to set User and Password in SIGFOX I/O Server configuration.
Callbacks
In order to use Sigfox callback services you must have a public IP address and you need to configure your router ports to let outside traffic to get into your network to your Hsyco. You also have to set callbackkey option and callbackport option (if the default 4445 is already in use or if you are using more instances of SIGFOX driver) in SIGFOX I/O Server options.
Every time Sigfox Cloud receive a message from a device it immediately propagates it to your SIGFOX driver, filling all message informations into an URL. Callback messages must be configured in Sigfox backend (you can configure callbacks for each device type associated to your account) choosing channel "URL" and composing the URL in the following format:
http://<public_ip_address>:<port>/hsyco/sigfox/<I/O_server_name>?key=<callbackkey>&id={device}&field1={var1}&field2={var2}&field3={var3}...
<port> is the public port opened on your router, <callbackkey> corresponds to callbackkey option of SIGFOX I/O Server. The URL fields "key" and "id" must be always present. The URL fields "field1", "field2", "field3", etc.. are optionals and can be set accordingly to the type of callback you are configuring in Sigfox backend; fields order is irrelevant. URL fields must be separated with '&' character.
E.g.
http://93.45.12.54:7777/hsyco/sigfox/sgfx?key=Abc1234&id={BE1234}&time={time}&data={data}&seqNumber={seqNumber}
Below are reported all URL fields that SIGFOX driver can process:
ID | Description |
---|---|
id | device ID |
time | timestamp (in Epoch time) of the message |
data | message content |
seqNumber | sequential number of the message |
batt | device battery voltage |
temp | device temperature (C˚) |
lqi | link quality indicator (as reported in Datapoints section) |
deviceTypeId | the ID of the device type in which this device is grouped |
Device Models
You can assign a model to each of your devices by modifying directly the file "sigfox-devices_<I/O_Server_name>.ini" (as described above) or using the SIGFOX Utility. By assigning a model to a device the SIGFOX driver can decode raw messages coming from that device accordingly to its communication protocol, this will generate more informations and relatives datapoints.
Actually the only device model supported by SIGFOX driver is the sequent:
ID | Protocol |
---|---|
eccoswitch | Ecco Switch protocol firmware V2 |
SIGFOX Utility
Use the SIGFOX Utility to automatically discover new devices or configure existing ones.
Datapoints
ID | Value | R/W | Description |
---|---|---|---|
connection | online | R | the driver is ready to accept incoming messages from Sigfox Cloud |
offline | R | initialization of the driver failed or loop cycle failed | |
devicetype.<devicetypeId>.name | <text> | R | the name of the device type corresponding to devicetypeId (only obtainable with API) |
device.<deviceId>.devicetype | <text> | R | the ID of the device type in which deviceId is grouped |
device.<deviceId>.name | <text> | R | the name of deviceId (only obtainable with API) |
device.<deviceId>.lastseen | <ts> | R | timestamp (in Epoch time) of the last message sent by deviceId |
device.<deviceId>.msg | <text> | R | content of the last message sent by deviceId |
device.<deviceId>.token.end | <ts> | R | deviceId token end date (in Epoch time) (only obtainable with API) |
device.<deviceId>.lqi | 0 | R | link quality indicator (computed from the last message received by Sigfox Cloud). 0=limit, 1=average, 2=good, 3=excellent, 4=not available |
1 | R | ||
2 | R | ||
3 | R | ||
4 | R | ||
device.<deviceId>.batt.tx | <val> | R | battery voltage (during transmission) of deviceId |
device.<deviceId>.batt.idle | <val> | R | battery voltage (in idle state) of deviceId |
device.<deviceId>.temp | <val> | R | internal temperature (C˚) of deviceId |
eccoswitch
Below are reported all datapoints generated from incoming messages from eccoswitch model devices. Those datapoints are in addition to SIGFOX I/O Server standard datapoints.
ID | Value | R/W | Description |
---|---|---|---|
device.<deviceId>.msg.test | 1 | R | status change on button "test" of deviceId |
0 | R | no status change on button "test" of deviceId | |
device.<deviceId>.msg.in.<n> | 1 | R | status change on input <n> of deviceId |
0 | R | no status change on input <n> of deviceId | |
device.<deviceId>.batt.idle | <val> | R | battery voltage (in idle state) of deviceId |