RACKPDU

From HSYCO
Revision as of 18:13, 14 June 2017 by Ulde (talk | contribs)
Jump to navigation Jump to search

The APC by Schneider Electric Rack Power Distribution Unit (PDU) may be used as a stand-alone, network- manageable power distribution device or up to four devices can be connected together using one network connection. The Rack PDU provides real-time remote monitoring of connected loads.

The HSYCO RACKPDU driver supports the AP88XX and AP78XXB Metered models.

IO Server RACKPDU.jpg

Communication

Connect the WXT520 to HSYCO through a direct serial connection or a supporter TCP/IP to serial gateway.

The default RS-232 parameters are:

Baud rate 19200
Data bits 8
Stop bit 1
Parity none
Flow control none

WXT520 configuration

The WXT520 must be configured to automatically send all relevant measured data to the serial port using its proprietary ASCII protocol.

Select the ASCII protocol and uncheck the "Polling only" option, so that automatic transmission is enabled. If the "Response with CRC" option is enabled, the WXT520 driver will check the CRC in received messages and discard messages with CRC errors.

The composite message transmission interval should be set to no more than 30 seconds, otherwise the driver could be occasionally restarted due to the intervention of the keep-alive watch-dog.


IO Server WXT520 configuration.png

HSYCO Configuration

Add a WXT520 I/O Server in the I/O Servers section of the Settings and set its parameters:

Communication

  • Comm ID: select the comm port connected to the device.

High Availability

  • Shutdown when inactive: defaults to true.

Options

ID Default Values Description
gui false true enable support for the UISET actions
false disable UI support
altitude 0 integer number the station's installation altitude above mean sea level.

This optional parameter is used to convert the measured local atmospheric pressure to mean sea level pressure (MSLP).

The conversion function takes into account the altitude and local temperature.

If this paramter is not set or set to 0, the measured pressure value will be returned unmodified.

Datapoints

All measured values returned as datapoints use the units as set in the WXT520. The unit is not returned in the datapoint value.


ID Value R/W Description
status online R connection established
offline R HSYCO can’t connect to the WXT520
sn <value> R wind speed minimum (m/s, km/h, mph, knots)
sm <value> R wind speed average (m/s, km/h, mph, knots)
sx <value> R wind speed maximum (m/s, km/h, mph, knots)
dn <value> R wind direction minimum (deg)
dm <value> R wind direction average (deg)
dx <value> R wind direction maximum (deg)
pa <value> R air pressure (hPa, Pa, bar, mmHg, inHg), converted to mean sea level pressure if the altitude option is set
ta <value> R air temperature (C, F)
tp <value> R internal temperature (C, F)
ua <value> R relative humidity (%RH)
rc <value> R rain accumulation (mm, in)
rd <value> R rain duration (s)
ri <value> R rain intensity (mm/h, in/h)
rp <value> R rain peak intensity (mm/h, in/h)
hc <value> R hail accumulation (hits/cm2, hits/in2, hits)
hd <value> R hail duration (s)
hi <value> R hail intensity (hits/cm2h, hits/in2h, hits/ h)
hp <value> R hail peak intensity (hits/cm2h, hits/in2h, hits/ h)
th <value> R heating temperature (C, F)
vh <value> R heating voltage (V)
vs <value> R supply voltage (V)
vr <value> R 3.5 V ref. voltage (V)
id <value> R information field

UISET Actions

ID Attribute Set to Description
sn value <value> <unit> wind speed minimum (m/s, km/h, mph, knots)
sm value <value> <unit> wind speed average (m/s, km/h, mph, knots)
sx value <value> <unit> wind speed maximum (m/s, km/h, mph, knots)
dn value <value> <unit> wind direction minimum (deg)
dm value <value> <unit> wind direction average (deg)
dn value <value> <unit> wind direction minimum (deg)
dx value <value> <unit> wind direction maximum (deg)
pa value <value> <unit> air pressure (hPa, Pa, bar, mmHg, inHg), converted to mean sea level pressure if the altitude option is set
ta value <value> <unit> air temperature (C, F)
tp value <value> <unit> internal temperature (C, F)
ua value <value> <unit> relative humidity (%RH)
rc value <value> <unit> rain accumulation (mm, in)
rd value <value> <unit> rain duration (s)
ri value <value> <unit> rain intensity (mm/h, in/h)
rp value <value> <unit> rain peak intensity (mm/h, in/h)
hc value <value> <unit> hail accumulation (hits/cm2, hits/in2, hits)
hd value <value> <unit> hail duration (s)
hi value <value> <unit> hail intensity (hits/cm2h, hits/in2h, hits/ h)
hp value <value> <unit> hail peak intensity (hits/cm2h, hits/in2h, hits/ h)
th value <value> <unit> heating temperature (C, F)
vh value <value> <unit> heating voltage (V)
vs value <value> <unit> supply voltage (V)
vr value <value> <unit> 3.5 V ref. voltage (V)
id value <value> <unit> information field

Release Notes

3.4.0

  • initial version release


Vaisala is a registered trademarks of Vaisala Oyj.