Difference between revisions of "SIGFOX"
Line 145: | Line 145: | ||
|- | |- | ||
− | |rowspan=" | + | |rowspan="5" |device.<deviceId>.lqi |
|0 | |0 | ||
|R | |R | ||
Line 151: | Line 151: | ||
|- | |- | ||
|1 | |1 | ||
+ | |R | ||
+ | |- | ||
+ | |2 | ||
+ | |R | ||
+ | |- | ||
+ | |3 | ||
+ | |R | ||
+ | |- | ||
+ | |4 | ||
|R | |R | ||
Revision as of 09:40, 20 October 2020
Sigfox is a global network operator founded that builds wireless networks to connect low-power objects such as electricity meters and smartwatches, which need to be continuously on and emitting small amounts of data. This driver allows you to communicate with Sigfox Cloud in order to retrieve messages and status updates collected from devices. As reported in the Sigfox Backend each device is grouped into a device type.
Contents
HSYCO Configuration
Add the SIGFOX I/O Server in the I/O Servers section of the Settings and set its parameters:
Authentication
- User: optional API username
- Password: optional API password
Devices list file
At the first run of SIGFOX driver a file named "sigfox-devices_<I/O_Server_name>.ini" will be created . This file can contain a series of line, each line represents informations of a single device and can have the following format:
<device_id>:name=<device_name>,model=<device_model>
<device_id>:model=<device_model>,name=<device_name>
<device_id>:name=<device_name>
<device_id>:model=<device_model>
<device_id>
E.g.
BE1234:name=homesensor,model=eccoswitch
BE1234:model=eccoswitch,name=homesensor
BE1234:name=homesensor
BE1234:model=eccoswitch
BE1234
Device id must be present in each line while name and model are optional. Device identifiers are considered as case insensitive by the SIGFOX I/O Server, so there can't be two identifiers with the same sequence of characters in upper/lower case, e.g. "BE1234" and "be1234" are considered the same.
Options
ID | Default | Values | Description |
---|---|---|---|
startupevents | true | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
acceptunknown | false | true | accept incoming messages from devices whose id isn't specified in sigfox-devices.ini |
false | doesn't accept incoming messages from devices whose id isn't specified in sigfox-devices.ini | ||
callbackport | <portNumber> | internal port used to receive incoming callback messages from Sigfox Cloud | |
callbackkey | <text> | key used in Sigfox URL callbacks to receive incoming callback messages |
SIGFOX Utility
Use the SIGFOX Utility to automatically discover new devices or configure existing ones.
Datapoints
ID | Value | R/W | Description |
---|---|---|---|
connection | online | R | the driver is ready to accept incoming messages from Sigfox Cloud |
offline | R | initialization of the driver failed or loop cycle failed | |
devicetype.<devicetypeId>.name | <text> | R | the name of the device type corresponding to devicetypeId (obtainable only with API) |
device.<deviceId>.devicetype | <text> | R | the ID of the device type in which deviceId is grouped |
device.<deviceId>.name | <text> | R | the name of deviceId (obtainable only with API) |
device.<deviceId>.lastseen | <ts> | R | timestamp (in Epoch time) of the last message sent by deviceId |
device.<deviceId>.msg | <text> | R | last message sent by deviceId (Hexadecimal format) |
device.<deviceId>.token.end | <ts> | R | deviceId token end date (in Epoch time) (obtainable only with API) |
device.<deviceId>.lqi | 0 | R | link quality indicator (computed from the last message received). 0=limit, 1=average, 2=good, 3=excellent, 4=not available |
1 | R | ||
2 | R | ||
3 | R | ||
4 | R |
Release Notes
3.8.0
- initial release