Difference between revisions of "Lares4"
Jump to navigation
Jump to search
(Created page with "The KSENIA lares 16IP/48IP/128IP are multi-area security systems. The integration with HSYCO can be accomplished via direct control through Ethernet connection. The I/O Server...") |
|||
Line 1: | Line 1: | ||
− | The KSENIA lares | + | The KSENIA lares 4.0 are multi-area security systems. The I/O Server has been tested on unit with firmware version 1.72.2 and web server version 1.32.7. Actually this driver runs only in HTTP mode (port 80 is set by default), so connection is not secure. |
+ | |||
+ | |||
+ | == HSYCO Configuration == | ||
+ | Add a KSENIA I/O Server in the [[Settings#I/O Servers|I/O Servers section of the Settings]] and set its parameters: | ||
+ | |||
+ | === Communication === | ||
+ | *'''IP Address''': host name or IP address of the panel | ||
+ | *'''IP Port''': TCP/IP port assigned to the panel's web server | ||
+ | |||
+ | === Authentication === | ||
+ | *'''User''': username to access the web server | ||
+ | *'''Password''': password to access the web server | ||
+ | |||
+ | === High Availability === | ||
+ | *'''Shutdown when inactive''': defaults to false. | ||
+ | |||
+ | === Options === | ||
+ | |||
+ | {| class="wikitable" | ||
+ | !ID | ||
+ | !Default | ||
+ | !Values | ||
+ | !Description | ||
+ | |||
+ | |- | ||
+ | |||
+ | |rowspan="2"|startupevents | ||
+ | |rowspan="2"|false | ||
+ | |true | ||
+ | |generate IO events also during the driver’s start-up phase | ||
+ | |- | ||
+ | |false | ||
+ | |start generating events only after HSYCO is aligned with the current status of the system | ||
+ | |||
+ | |- | ||
+ | |||
+ | |pollinterval | ||
+ | |1000 | ||
+ | |n > 1000 | ||
+ | |the data acquisition interval, in milliseconds | ||
+ | |||
+ | |- | ||
+ | |||
+ | |logsize | ||
+ | |20 | ||
+ | |n ≥ 0 | ||
+ | |the number of log lines to display in the UI object | ||
+ | |||
+ | |- | ||
+ | |||
+ | |rowspan="2"|gui | ||
+ | |rowspan="2"|true | ||
+ | |true | ||
+ | |enable the UISET "visible" field for all system zones | ||
+ | |- | ||
+ | |false | ||
+ | |disable the UISET "visible" field for all system zones | ||
+ | |||
+ | |} |
Revision as of 11:27, 28 May 2021
The KSENIA lares 4.0 are multi-area security systems. The I/O Server has been tested on unit with firmware version 1.72.2 and web server version 1.32.7. Actually this driver runs only in HTTP mode (port 80 is set by default), so connection is not secure.
Contents
HSYCO Configuration
Add a KSENIA I/O Server in the I/O Servers section of the Settings and set its parameters:
Communication
- IP Address: host name or IP address of the panel
- IP Port: TCP/IP port assigned to the panel's web server
Authentication
- User: username to access the web server
- Password: password to access the web server
High Availability
- Shutdown when inactive: defaults to false.
Options
ID | Default | Values | Description |
---|---|---|---|
startupevents | false | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
pollinterval | 1000 | n > 1000 | the data acquisition interval, in milliseconds |
logsize | 20 | n ≥ 0 | the number of log lines to display in the UI object |
gui | true | true | enable the UISET "visible" field for all system zones |
false | disable the UISET "visible" field for all system zones |