Difference between revisions of "Protege"

From HSYCO
Jump to navigation Jump to search
Line 33: Line 33:
 
|pin
 
|pin
 
|the user PIN that the driver uses when sending commands to the Protege system. It must be a valid user code, able to engage and disengage the panel.
 
|the user PIN that the driver uses when sending commands to the Protege system. It must be a valid user code, able to engage and disengage the panel.
|-
 
 
|model
 
|
 
|string
 
|the system’s model. Use one of the following values: TP16-256, TP8-64BUS, TP8-96VIDEO, TP8-96GSM, TP16-512GSM, TP8-88, TP8-88P, TP20-440
 
 
|-
 
|-
  
Line 59: Line 53:
 
|-
 
|-
  
|rowspan="2"|userlogs
+
|rowspan="2"|debug
 
|rowspan="2"|false
 
|rowspan="2"|false
 
|true
 
|true
|generates logs that can be viewed with the userlist object, and can be selected to generate user events
+
|generates additional logs that can be viewed in verbose mode
 
|-
 
|-
 
|false
 
|false
|logs for userlist objects disabled. Normal text logs are generated even when this option is false
+
|debu log disabled
 
|-
 
|-
  

Revision as of 07:21, 14 August 2019

Protege is a server based architecture enabling you to securely manage, control and monitor a number of users, doors, areas, and other devices. The integration with HSYCO can be accomplished with a TCP/IP network connection.

ProtegeGXServer needs to be configured to accept a connection on a defined TCP/IP port with the ICT Automation and Control Service protocol. A PIN must be set (4 to 6 digits) Disable encryption and checksum Select Little Endian format Enable Login Block after PIN error

HSYCO Configuration

Add a PROTEGE I/O Server in the I/O Servers section of the Settings and set its parameters:

Communication

  • IP Address: the ICT Protege Server panel address
  • IP Port: TCP/IP port enabled on the ICT Protege Server

High Availability

  • Shutdown when inactive: defaults to true.

Options

ID Default Values Description
pin pin the user PIN that the driver uses when sending commands to the Protege system. It must be a valid user code, able to engage and disengage the panel.
startupevents false true generate IO events also during the driver’s start-up phase
false start generating events only after HSYCO is aligned with the current status of the system
gui true true enable support of the tecnoalarm Web interface object
false disable support of the tecnoalarm Web interface object
debug false true generates additional logs that can be viewed in verbose mode
false debu log disabled
logsize 50 n ≥ 0 the number of log events shown in the tecnoalarm Web object. Set to 0 to hide the log in the tecnoalarm object
pass string the passphrase used to encrypt the TCP/IP traffic. If the Tecnoalarm system doesn’t support the passphrase, you should omit this parameter
polltime 1000 n ≥ 0 the data polling interval, in milliseconds. Shorter time improve the response of the system, but increase the load on the CPU of both HSYCO and the Tecnoalarm system