|the user PIN that the driver uses when sending commands to the Protege system. It must be a valid user code, able to engage and disengage the panel. | |the user PIN that the driver uses when sending commands to the Protege system. It must be a valid user code, able to engage and disengage the panel. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
Line 59: | Line 53: | ||
|- | |- | ||
− | |rowspan="2"| | + | |rowspan="2"|debug |
|rowspan="2"|false | |rowspan="2"|false | ||
|true | |true | ||
− | |generates logs that can be viewed | + | |generates additional logs that can be viewed in verbose mode |
|- | |- | ||
|false | |false | ||
− | | | + | |debu log disabled |
|- | |- | ||
Revision as of 07:21, 14 August 2019
Protege is a server based architecture enabling you to securely manage, control and monitor a number of users, doors, areas, and other devices. The integration with HSYCO can be accomplished with a TCP/IP network connection.
ProtegeGXServer needs to be configured to accept a connection on a defined TCP/IP port with the ICT Automation and Control Service protocol. A PIN must be set (4 to 6 digits) Disable encryption and checksum Select Little Endian format Enable Login Block after PIN error
HSYCO Configuration
Add a PROTEGE I/O Server in the I/O Servers section of the Settings and set its parameters:
Communication
- IP Address: the ICT Protege Server panel address
- IP Port: TCP/IP port enabled on the ICT Protege Server
High Availability
- Shutdown when inactive: defaults to true.
Options
ID | Default | Values | Description |
---|---|---|---|
pin | pin | the user PIN that the driver uses when sending commands to the Protege system. It must be a valid user code, able to engage and disengage the panel. | |
startupevents | false | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
gui | true | true | enable support of the tecnoalarm Web interface object |
false | disable support of the tecnoalarm Web interface object | ||
debug | false | true | generates additional logs that can be viewed in verbose mode |
false | debu log disabled | ||
logsize | 50 | n ≥ 0 | the number of log events shown in the tecnoalarm Web object. Set to 0 to hide the log in the tecnoalarm object |
pass | string | the passphrase used to encrypt the TCP/IP traffic. If the Tecnoalarm system doesn’t support the passphrase, you should omit this parameter | |