Difference between revisions of "Dea Xensity"

From HSYCO
Jump to navigation Jump to search
Line 85: Line 85:
 
|0
 
|0
 
|R
 
|R
|Connection with X16-ER16L is not stable
+
|connection with X16-ER16L is not stable
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Connection with X16-ER16L is stable
+
|connection with X16-ER16L is stable
 
|-
 
|-
  
Line 95: Line 95:
 
|0
 
|0
 
|R
 
|R
|Connection with sensors is not stable
+
|connection with sensors is not stable
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
||Connection with sensors is stable
+
||connection with sensors is stable
 
|-
 
|-
  
Line 105: Line 105:
 
|0
 
|0
 
|R
 
|R
|Bus sensors power supply not ok
+
|bus sensors power supply not ok
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Bus sensors power supply ok
+
|bus sensors power supply ok
 
|-
 
|-
  
Line 115: Line 115:
 
|0
 
|0
 
|R
 
|R
|No alarms
+
|no alarms
 
|-
 
|-
 
|1
 
|1
Line 125: Line 125:
 
|0
 
|0
 
|R
 
|R
|No tamper alarms
+
|no tamper alarms
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|At least one tamper alarm is active - not filtered-
+
|at least one tamper alarm is active - not filtered-
 
|-
 
|-
  
Line 145: Line 145:
 
|0
 
|0
 
|R
 
|R
|Tamper input is not active
+
|tamper input is not active
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Tamper input is active
+
|tamper input is active
 
|-
 
|-
  
Line 156: Line 156:
 
|0
 
|0
 
|R
 
|R
|Battery charge ok
+
|battery charge ok
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Battery charge is low
+
|battery charge is low
 
|-
 
|-
  
Line 166: Line 166:
 
|0
 
|0
 
|R
 
|R
|Autotest is ok
+
|autotest is ok
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|At least one sensor failed autotest
+
|at least one sensor failed autotest
 
|-
 
|-
  
Line 176: Line 176:
 
|0
 
|0
 
|R
 
|R
|Sensors bus is ok
+
|sensors bus is ok
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Sensors bus fault
+
|sensors bus fault
 
|-
 
|-
  
Line 186: Line 186:
 
|0
 
|0
 
|R
 
|R
|Current on sensors bus is ok
+
|current on sensors bus is ok
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Over current on sensors bus
+
|over current on sensors bus
 
|-
 
|-
  
Line 196: Line 196:
 
|0
 
|0
 
|R
 
|R
|No sensors in tamper alarm
+
|no sensors in tamper alarm
 
|-
 
|-
 
|1
 
|1
Line 206: Line 206:
 
|0
 
|0
 
|R
 
|R
|Power ok
+
|power ok
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Power fail
+
|power fail
 
|-
 
|-
  
Line 216: Line 216:
 
|<v>
 
|<v>
 
|R
 
|R
|Power supply voltage <v> in mV
+
|power supply voltage <v> in mV
 
|-
 
|-
  
Line 223: Line 223:
 
|0
 
|0
 
|R
 
|R
|Open collector output <n> is open
+
|open collector output <n> is open
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Open collector output <n> is closed
+
|open collector output <n> is closed
 
|-
 
|-
  
Line 233: Line 233:
 
|0
 
|0
 
|R
 
|R
|Relay <n> is open
+
|relay <n> is open
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Relay <n> is closed
+
|relay <n> is closed
 
|-
 
|-
  
Line 243: Line 243:
 
|0
 
|0
 
|R
 
|R
|Input <n> is open
+
|input <n> is open
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|Input <n> is closed
+
|input <n> is closed
 
|-
 
|-
  
Line 253: Line 253:
 
|<string>
 
|<string>
 
|R
 
|R
|Serial number <string>
+
|serial number <string>
 
|-
 
|-
  
Line 259: Line 259:
 
|<n>
 
|<n>
 
|R
 
|R
|Global security level <n>
+
|global security level <n>
 
|-
 
|-
  
Line 265: Line 265:
 
|<n>
 
|<n>
 
|R
 
|R
|Hardware type <n>
+
|hardware type <n>
 
|-
 
|-
  
|rowspan="2" |node.<n>.loop.<l>.sensor.<nowiki><s></nowiki>.prealarm
+
|rowspan="2" |z<n>.alarm
 
|0
 
|0
 
|R
 
|R
|not in prealarm
+
|zone <n> not on alarm
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|prealarm
+
|zone <n> on alarm
 
|-
 
|-
  
|rowspan="2" |node.<n>.loop.<l>.sensor.<nowiki><s></nowiki>.alarm
+
|rowspan="2" |z<n>.alarm.mem
 
|0
 
|0
 
|R
 
|R
|not in alarm
+
|zone <n> not on alarm memory
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|alarm
+
|zone <n> on alarm memory
 
|-
 
|-
  
|rowspan="2" |node.<n>.loop.<l>.sensor.<nowiki><s></nowiki>.fault
+
|rowspan="2" |z<n>.armed
 
|0
 
|0
 
|R
 
|R
|not in fault
+
|zone <n> disarmed
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|fault
+
|zone <n> armed
 
|-
 
|-
  
|rowspan="2" |node.<n>.loop.<l>.sensor.<nowiki><s></nowiki>.test
+
|rowspan="2" |z<n>.bypass
 
|0
 
|0
 
|R
 
|R
|not in test
+
|zone <n> not bypassed
 
|-
 
|-
 
|1
 
|1
 
|R
 
|R
|in test
+
|zone <n> bypassed
|-
 
 
 
|rowspan="2" |node.<n>.loop.<l>.sensor.<nowiki><s></nowiki>.dis
 
|0
 
|R
 
|enabled
 
|-
 
|1
 
|R
 
|disabled
 
|-
 
 
 
 
 
|rowspan="2" |node.<n>.loop.<l>.module.<nowiki><s></nowiki>.prealarm
 
|0
 
|R
 
|not in prealarm
 
|-
 
|1
 
|R
 
|prealarm
 
|-
 
 
 
|rowspan="2" |node.<n>.loop.<l>.module.<nowiki><s></nowiki>.alarm
 
|0
 
|R
 
|not in alarm
 
|-
 
|1
 
|R
 
|alarm
 
|-
 
 
 
|rowspan="2" |node.<n>.loop.<l>.module.<nowiki><s></nowiki>.fault
 
|0
 
|R
 
|not in fault
 
|-
 
|1
 
|R
 
|fault
 
|-
 
 
 
|rowspan="2" |node.<n>.loop.<l>.module.<nowiki><s></nowiki>.test
 
|0
 
|R
 
|not in test
 
|-
 
|1
 
|R
 
|in test
 
|-
 
 
 
|rowspan="2" |node.<n>.loop.<l>.module.<nowiki><s></nowiki>.dis
 
|0
 
|R
 
|enabled
 
|-
 
|1
 
|R
 
|disabled
 
 
|-
 
|-
  

Revision as of 18:19, 23 March 2020

DEA XENSITY is a Point ID intrusion detection system using special piezoelectric sensors for the protection of doors, windows, glass surfaces, security grilles and walls. This driver is compatible with the following controllers: Xensity128, Xensity64, Xensity32. Make sure to install the latest available firmware.

Communication

DEA XENSITY panels can be connected via ethernet. A valid IP address must be assigned to the controller using the configuration software.

Note  In case of multiple DEA XENSITY IO Servers running on the same HSYCO Server you must assign a different UDP port to each XENSITY driver

HSYCO Configuration

Add a XENSITY I/O Server in the I/O Servers section of the Settings and set its parameters:

Communication

  • Address: IP address of the XENSITY controller (mandatory)
  • Port: UDP port (mandatory)

High Availability

  • Shutdown when inactive: defaults to false.

Options

ID Default Values Description
startupevents false true generate IO events also during the driver’s start-up phase
false start generating events only after HSYCO is aligned with the current status of the system
pollinterval 1000 n ≥ 0 the data polling interval, in milliseconds. Shorter time improve the response of the system, but increase the load on the CPU of both HSYCO and the Xensity system

Datapoints

ID Value R/W Description
connection online R connection established
offline R HSYCO can't connect to the panel
alarm 0 R no alarms
1 R at least one zone of this controller on alarm
link.x16 0 R connection with X16-ER16L is not stable
1 R connection with X16-ER16L is stable
link.sens 0 R connection with sensors is not stable
1 R connection with sensors is stable
bus.power 0 R bus sensors power supply not ok
1 R bus sensors power supply ok
alarm.nf 0 R no alarms
1 R At least one alarm is active - not filtered-
tamper.nf 0 R no tamper alarms
1 R at least one tamper alarm is active - not filtered-
arm 0 R arm is not active
1 R arm is active
in.tamper 0 R tamper input is not active
1 R tamper input is active
battery.low 0 R battery charge ok
1 R battery charge is low
test.fail 0 R autotest is ok
1 R at least one sensor failed autotest
bus.fault 0 R sensors bus is ok
1 R sensors bus fault
bus.overcurr 0 R current on sensors bus is ok
1 R over current on sensors bus
tamper 0 R no sensors in tamper alarm
1 R At least one sensor in tamper alarm
power.fault 0 R power ok
1 R power fail
vin <v> R power supply voltage <v> in mV
oc<n> 0 R open collector output <n> is open
1 R open collector output <n> is closed
rel<n> 0 R relay <n> is open
1 R relay <n> is closed
in<n> 0 R input <n> is open
1 R input <n> is closed
serial <string> R serial number <string>
seclev <n> R global security level <n>
pn <n> R hardware type <n>
z<n>.alarm 0 R zone <n> not on alarm
1 R zone <n> on alarm
z<n>.alarm.mem 0 R zone <n> not on alarm memory
1 R zone <n> on alarm memory
z<n>.armed 0 R zone <n> disarmed
1 R zone <n> armed
z<n>.bypass 0 R zone <n> not bypassed
1 R zone <n> bypassed

Release Notes

3.7.0

  • initial release