Difference between revisions of "TLABQ"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
− | The TLAB-Q is a multi-area security system | + | The TLAB-Q is a multi-area security system with four different models; the model Quadrio supports only one area, the models Small, Medium, Large support four areas. Each area is divided into four groups (A,B,C,D) |
== HSYCO Configuration == | == HSYCO Configuration == |
Revision as of 12:54, 2 March 2021
The TLAB-Q is a multi-area security system with four different models; the model Quadrio supports only one area, the models Small, Medium, Large support four areas. Each area is divided into four groups (A,B,C,D)
Contents
HSYCO Configuration
Add the TLABQ I/O Server in the I/O Servers section of the Settings and set its parameters:
Communication
- IP Address: host name or IP address of the panel
- IP Port: TCP/IP port assigned to the panel's web server
Authentication
- User: username to access the web server
- Password: password to access the web server
Options
ID | Default | Values | Description |
---|---|---|---|
startupevents | false | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
gui | true | true | enable the UISET "visible" field for all system zones |
false | disable the UISET "visible" field for all system zones | ||
pollinterval | 1000 | n > 1000 | the data acquisition interval, in milliseconds |
logsize | 400 | n ≥ 0 | the number of log lines to display in the UI object |
Datapoints
ID | Value | R/W | Description |
---|---|---|---|
connection | online | R | connection established |
offline | R | HSYCO can't connect to the panel | |
id | Q | R | security panel series identification |
model | Quadrio | R | security panel model |
Small | |||
Medium | |||
Large | |||
fw | <text> | R | firmware version running on the security panel |
dataconfig | 0..999 | R | data configuration version |
accesstype | admin | R | connection established |
no_valid_access | R | HSYCO can't connect to the panel | |
<user_index> | R | HSYCO can't connect to the panel | |
temp | <val> | R | security panel temperature (C°) |
credit | <val> | R | SIM credit (€) |
gsm.fault | 1 | R | gsm error detected |
0 | R | no gsm error | |
gsm.fault.cause | 1 | R | network registration error |
2 | R | no SIM | |
3 | R | no service provider | |
4 | R | low signal | |
5 | R | no response to sent command | |
6 | R | SIM pin block | |
pstn.fault | 1 | R | PSTN fault detected |
0 | R | no PSTN fault | |
nopower | 1 | R | no power supply |
0 | R | power supply in normal state | |
nopower.device | 65534 | R | system detected lack of power supply |
<n> | R | index of device that detected lack of power supply | |
batt.fault | 1 | R | battery fault detected |
0 | R | no battery fault | |
batt.fault.device | 65534 | R | system detected battery fault |
<n> | R | index of device that detected battery fault | |
tamper | 1 | R | tamper on a device detected |
0 | R | no tamper detected | |
tamper.device | 65534 | R | system in tampering |
<n> | R | index of device in tampering | |
coercion | 1 | R | user coercion detected |
0 | R | no user coercion detected | |
coercion.user | <n> | R | index of user under duress |
radiointerference | 1 | R | radiointerference detected |
0 | R | no radiointerference detected | |
radiozone.fault | 1 | R | radio zone fault detected |
0 | R | no radio zone fault detected | |
radiozone.fault.zone | <n> | R | index of radio zone fault |
theft | 1 | R | theft detected |
0 | R | no theft detected | |
theft.device | <n> | R | index of device that detected theft |
medemergency | 1 | R | medical emergency detected |
0 | R | no medical emergency detected | |
medemergency.device | <n> | R | index of device that detected medical emergency |
radiohooter.fault | 1 | R | radio hooter fault detected |
0 | R | no radio hooter fault detected | |
radiohooter.fault.device | <n> | R | index of device that detected radio hooter fault |
radiokeyboard.fault | 1 | R | radio keyboard fault detected |
0 | R | no radio keyboard fault detected | |
radiokeyboard.fault.device | <n> | R | index of device that detected radio keyboard fault |
radiohooter.ids | <text> | R | list of radio hooter indexes in tampering |
remoteaccess | 1 | R | remote access detected |
0 | R | no remote access detected | |
a<n>.name | <text> | R/W | name of area <n> (max. 16 characters) |
a<n>.ins | 0 | W | disarm all groups in area <n> |
1 | W | arm all groups in area <n> | |
a<n>.alarmgroups | <text> | R | list of groups, in area <n>, in alarm state |
a<n>.tampergroups | <text> | R | list of groups, in area <n>, in tampering |
a<n>.prealarmgroups | <text> | R | list of groups, in area <n>, in pre-alarm state |
a<n>.blindgroups | <text> | R | list of groups, in area <n>, in blind state |
a<n>.group.<a,b,c,d>.en | 0 | R | group <a,b,c,d> in area <n> is disabled |
1 | R | group <a,b,c,d> in area <n> is enabled | |
a<n>.group.<a,b,c,d>.ins | 0 | R/W | group <a,b,c,d> in area <n> is disarmed |
1 | R/W | group <a,b,c,d> in area <n> is armed | |
a<n>.group.<a,b,c,d>.name | <text> | R/W | name of group <a,b,c,d> in area <n> (max. 16 characters) |
totaloutputs | <n> | R | total outputs number associated to the security panel |
totalradiooutputs | <n> | R | total radio outputs number associated to the security panel |
o<n>.status | 0 | R | output n doesn't exist |
1 | R | output n not configured and disabled | |
2 | R | output n not configured and enabled | |
11 | R | output n configured and disabled | |
12 | R | output n configured and enabled | |
o<n> | 0 | W | disable output n |
1 | W | enable output n | |
o<n>.name | <text> | W | change name of output n (max. 16 characters) |
o<n>.sec | 0 | W | remove timing on output n |
<k> | W | output n will change status (enable/disable) after k seconds | |
totalwiredzones | <n> | R | total wired zones number |
totalradiozones | <n> | R | total radio zones number |
z<n>.status | 0 | R | zone n not configured |
1 | R | zone n excluded | |
2 | R | zone n in normal state | |
3 | R | zone n in tampering | |
11 | R | zone n open internal contact | |
12 | R | zone n open external contact | |
13 | R | zone n open internal and external contacts | |
20 | R | alarm memory in zone n and all contacts closed | |
21 | R | alarm memory in zone n and internal contact open | |
22 | R | alarm memory in zone n and external contact open | |
23 | R | alarm memory in zone n and all contact open | |
40 | R | zone n in alarm and all contacts closed | |
41 | R | zone n in alarm and internal contact open | |
42 | R | zone n in alarm and all external contact open | |
43 | R | zone n in alarm and all contacts open |
User Interface
UISET Actions
ID | Attribute | Set to | |
---|---|---|---|
log | value | latest security log lines (as many as specified by the 'logsize' option) | |
log0 | value | latest security log (it will vanish after 5 seconds) | |
z<n>.not.configured | visible | true | zone n is not configured |
false | zone n is configured | ||
z<n>.excluded | visible | true | zone n is excluded |
false | zone n is not excluded | ||
z<n>.normal | visible | true | zone n is in normal state |
false | zone n is not in normal state | ||
z<n>.tamper | visible | true | zone n is in tampering |
false | zone n is not in tampering | ||
z<n>.open.internal | visible | true | internal contact open in zone n |
false | not internal contact open in zone n | ||
z<n>.open.external | visible | true | external contact open in zone n |
false | not external contact open in zone n | ||
z<n>.open.both | visible | true | both contacts open in zone n |
false | not both contacts open in zone n | ||
z<n>.alarm.memory.closed.both | visible | true | alarm memory in zone n and both contacts closed |
false | not alarm memory in zone n and both contacts closed | ||
z<n>.alarm.memory.open.internal | visible | true | alarm memory in zone n and internal contact open |
false | not alarm memory in zone n and internal contact open | ||
z<n>.alarm.memory.open.external | visible | true | alarm memory in zone n and external contact open |
false | not alarm memory in zone n and external contact open | ||
z<n>.alarm.memory.open.both | visible | true | alarm memory in zone n and both contacts open |
false | not alarm memory in zone n and both contacts open | ||
z<n>.alarm.closed.both | visible | true | alarm in zone n and both contacts closed |
false | not alarm in zone n and both contacts closed | ||
z<n>.alarm.open.internal | visible | true | alarm in zone n and internal contact open |
false | not alarm in zone n and internal contact open | ||
z<n>.alarm.open.external | visible | true | alarm in zone n and external contact open |
false | not alarm in zone n and external contact open | ||
z<n>.alarm.open.both | visible | true | alarm in zone n and both contacts open |
false | not alarm in zone n and both contacts open |
Release Notes
3.8.0
- initial release