Difference between revisions of "RACKPDU"

From HSYCO
Jump to navigation Jump to search
Line 65: Line 65:
 
|-
 
|-
  
|bklowload
+
|bklowload.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|bank low-load threshold current in amps
+
|bank N low-load threshold current in amps
 
|-
 
|-
  
|bknearover
+
|bknearover.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|bank near-overload threshold current in amps
+
|bank N near-overload threshold current in amps
 
|-
 
|-
  
|bkoverload
+
|bkoverload.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|bank overload threshold current in amps
+
|bank N overload threshold current in amps
 
|-
 
|-
  
Line 107: Line 107:
 
|-
 
|-
  
|phlowload
+
|phlowload.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|phase low-load threshold (amps)
+
|phase N low-load threshold (amps)
 
|-
 
|-
  
|phnearover
+
|phnearover.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|phase near-overload threshold (amps)
+
|phase N near-overload threshold (amps)
 
|-
 
|-
  
|phoverload
+
|phoverload.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|phase overload threshold (amps)
+
|phase N overload threshold (amps)
 
|-
 
|-
  
Line 131: Line 131:
 
|-
 
|-
  
|bkpeakcurr
+
|bkpeakcurr.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|bank peak current measurement in amps
+
|bank N peak current measurement in amps
 
|-
 
|-
  
|bkreading
+
|bkreading.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|bank current reading (measurement) in amps
+
|bank N current reading (measurement) in amps
 
|-
 
|-
  
Line 173: Line 173:
 
|-
 
|-
  
|phpeakcurr
+
|phpeakcurr.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|peak current measurement from a phase (amps)
+
|peak current measurement from phase N (amps)
 
|-
 
|-
  
|phreading.current
+
|phreading.current.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|measured current for a phase (amps)
+
|measured current for phase N (amps)
 
|-
 
|-
  
|phreading.voltage
+
|phreading.voltage.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|measured voltage for a phase (volts)
+
|measured voltage for phase N (volts)
 
|-
 
|-
  
|phreading.power
+
|phreading.power.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|measured power for a phase (watts)
+
|measured power for phase N (watts)
 
|-
 
|-
  
|phreading.appower
+
|phreading.appower.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|measured apparent power for a phase (va)
+
|measured apparent power for phase N(va)
 
|-
 
|-
  
|phreading.pf
+
|phreading.pf.<N>
 
|<value>
 
|<value>
 
|R
 
|R
|measured power factor for a phase
+
|measured power factor for phase N
 
|-
 
|-
  

Revision as of 18:44, 14 June 2017

The APC by Schneider Electric Rack Power Distribution Unit (PDU) may be used as a stand-alone, network- manageable power distribution device or up to four devices can be connected together using one network connection. The Rack PDU provides real-time remote monitoring of connected loads.

The HSYCO RACKPDU driver supports the AP88XX and AP78XXB Metered models.

IO Server RACKPDU.jpg

PDU Configuration

In order to be able to control the device with HSYCO SERVER, remote access to the command line interface via SSH must be enabled.

HSYCO Configuration

Add a RACKPDU I/O Server in the I/O Servers section of the Settings and set its parameters:

Communication

  • IP Address: the IP address of the device
  • IP Port: TCP/IP port to use (defaults to 22)
  • User: the SSH user (defaults to "apc")
  • Password: the SSH password (defaults to "apc").


High Availability

  • Shutdown when inactive: defaults to false.

Options

ID Default Values Description
startupevents false true generate IO events also during the driver’s start-up phase
false start generating events only after HSYCO is aligned with the current status of the system

Datapoints

All measured values returned as datapoints use the units as set in the PDU. The unit is not returned in the datapoint value.


ID Value R/W Description
connection online R connection established
offline R not connected to the PDU
bklowload.<N> <value> R bank N low-load threshold current in amps
bknearover.<N> <value> R bank N near-overload threshold current in amps
bkoverload.<N> <value> R bank N overload threshold current in amps
devlowload <value> R low-load threshold in kilowatts for the device
devnearover <value> R near-overload threshold in kilowatts for the device
devoverload <value> R overload threshold in kilowatts for the device
humreading <value> R humidity value from the sensor (%RH)
phlowload.<N> <value> R phase N low-load threshold (amps)
phnearover.<N> <value> R phase N near-overload threshold (amps)
phoverload.<N> <value> R phase N overload threshold (amps)
tempReading <value> R temperature value in Celsius
bkpeakcurr.<N> <value> R bank N peak current measurement in amps
bkreading.<N> <value> R bank N current reading (measurement) in amps
devpeakload <value> R peak power measurement in kilowatts from the device
devreading.power <value> R total power in kilowatts for the device
devreading.energy <value> R total energy in kilowatt-hours for the device
devreading.appower <value> R total apparent power in kilovolt amperes for the device
devreading.pf <value> R total power factor for the device
phpeakcurr.<N> <value> R peak current measurement from phase N (amps)
phreading.current.<N> <value> R measured current for phase N (amps)
phreading.voltage.<N> <value> R measured voltage for phase N (volts)
phreading.power.<N> <value> R measured power for phase N (watts)
phreading.appower.<N> <value> R measured apparent power for phase N(va)
phreading.pf.<N> <value> R measured power factor for phase N
hp <value> R hail peak intensity (hits/cm2h, hits/in2h, hits/ h)
th <value> R heating temperature (C, F)

Release Notes

3.6.0

  • initial version release


APC, StruxureWare, and PowerNet are trademarks owned by Schneider Electric Industries, S.A.S., or its affiliated companies. All other trademarks are property of their respective owners.