Protege is a server based architecture enabling you to securely manage, control and monitor a number of users, doors, areas, and other devices. The integration with HSYCO can be accomplished with a TCP/IP network connection.

  • ProtegeGXServer needs to be configured to accept a connection on a defined TCP/IP port with the ICT Automation and Control Service protocol.
  • A PIN must be set (4 to 6 digits)
  • Disable encryption and checksum
  • Select Little Endian format
  • Enable Login Block after PIN error


HSYCO Configuration

Add a PROTEGE I/O Server in the I/O Servers section of the Settings and set its parameters:

Communication

  • IP Address: the ICT Protege Server panel address
  • IP Port: TCP/IP port enabled on the ICT Protege Server

High Availability

  • Shutdown when inactive: defaults to true.

Options

ID Default Values Description
pin pin the user PIN that the driver uses when sending commands to the Protege system. It must be a valid user code, able to engage and disengage the panel.
startupevents false true generate IO events also during the driver’s start-up phase
false start generating events only after HSYCO is aligned with the current status of the system
gui true true enable support of the tecnoalarm Web interface object
false disable support of the tecnoalarm Web interface object
debug false true generates additional logs that can be viewed in verbose mode
false debug logging disabled
areaslist string list of all the areas that are declared on the panel. Areas could not be consecutive and special characters "-" and ";" are used for intervals definition. E.G. 0-3;5-9 means areas from 0 to 3, from 5 to 9. E.G. 4;15 means area number 4 and number 15
inputslist string list of all the inputs that are declared on the panel. Inputs could not be consecutive and special characters "-" and ";" are used for intervals definition. E.G. 0-3;5-9 means inputs from 0 to 3, from 5 to 9. E.G. 4;15 means input number 4 and input 15
outputslist string list of all the outputs that are declared on the panel. Outputs could not be consecutive and special characters "-" and ";" are used for intervals definition. E.G. 0-3;5-9 means outputs from 0 to 3, from 5 to 9. E.G. 4;15 means output number 4 and output 15
doorslist string list of all the doors that are declared on the panel. Doors could not be consecutive and special characters "-" and ";" are used for intervals definition. E.G. 0-3;5-9 means doors from 0 to 3, from 5 to 9. E.G. 4;15 means door number 4 and door 15
troubleinputslist string list of all the trouble inputs that are declared on the panel. Trouble inputs could not be consecutive and special characters "-" and ";" are used for intervals definition. E.G. 0-3;5-9 means trouble inputs from 0 to 3, from 5 to 9. E.G. 4;15 means trouble input number 4 and trouble input 15

Datapoints

ID Value R/W Description
connection online R connection established
offline R connection failed
panel.firmware.build <text> R firmware build of the panel
panel.firmware.type <text> R firmware type of the panel
panel.firmware.version <text> R firmware version of the panel
panel.hardware.version <text> R hardware version of the panel
panel.serial.number <text> R serial number of the panel
a<n>.armed 1 R area is armed
0 R area is disarmed
a<n>.state armed R area is armed
disarmed R area is disarmed
inputsopen R area is disarmed