Difference between revisions of "Wolf8Access"
Line 15: | Line 15: | ||
==== Protocol version 4.xx or higher ==== | ==== Protocol version 4.xx or higher ==== | ||
− | If using the WP-LAN Ethernet module the system works in DHCP mode, so you cannot set a static IP address. If you want a static IP address on your module please contact Wolf assistance before buying it. You have to set the serial number of the Wolf8Access MIND module in the I/O Server options. | + | If using the WP-LAN Ethernet module the system works in DHCP mode, so you cannot set a static IP address. If you want a static IP address on your module please contact Wolf assistance before buying it. |
+ | |||
+ | You have to set the serial number of the Wolf8Access MIND module in the I/O Server options. | ||
=== W-USB module === | === W-USB module === |
Revision as of 14:42, 12 May 2021
HSYCO integrates the 8Access system by Wolf Safety through USB or Ethernet connection.
Contents
Communication
W-LAN (or WP-LAN) module
Protocol version 3.xx or lower
If using the W-LAN Ethernet module, it must be configured using the Tibbo DS Manager tool.
You need to set its static IP address, port (default 1001) and serial communication parameters.
For the serial parameter, go to Settings > Channel1 tab and set the parameters as shown in the table below.
Protocol version 4.xx or higher
If using the WP-LAN Ethernet module the system works in DHCP mode, so you cannot set a static IP address. If you want a static IP address on your module please contact Wolf assistance before buying it.
You have to set the serial number of the Wolf8Access MIND module in the I/O Server options.
W-USB module
If using the W-USB module, just configure HSYCO to use the following serial parameters:
Baud rate | 115200 |
Data bits | 8 |
Stop bit | 1 |
Parity | none |
Flow control | none |
HSYCO Configuration
Add a WOLF8ACCESS I/O Server in the I/O Servers section of the Settings and set its parameters:
Communication
- Comm ID: select the comm port connected to the panel.
If using USB connection (W-USB module) crate a serial Comm port, otherwise, if using the Ethernet adapter (W-LAN module or WP-LAN), crate a server Comm port. For version 4.xx or higher, communication with the WP-LAN module implies TCP/IP protocol on port 8000.
Authentication
- Password: system password
High Availability
- Shutdown when inactive: defaults to true.
Options
ID | Default | Values | Description |
---|---|---|---|
serialnum | <val> | serial number of the Wolf8Access MIND board. Leave it empty for protocol 3.xx or lower |
Datapoints
Peripherals' numbers (p<n>) range from 0 to 7.
ID | Value | R/W | Description |
---|---|---|---|
connection | online | R | connection established |
offline | R | HSYCO can't connect to the device | |
p<n>.key | <pos> | R | peripheral <n> read the key saved in memory position <pos> |
p<n>.open | 1 | R | peripheral <n>'s door is open |
W | open peripheral <n>'s relay | ||
0 | R | peripheral <n>'s door is closed | |
p<n>.blocked | 1 | R | peripheral <n> is blocked (all non-manager keys disabled) |
W | block peripheral <n> (disable all non-manager keys) | ||
0 | R | peripheral <n> is un-blocked (all non-manager keys restored) | |
W | un-block peripheral <n> (restore all non-manager keys) | ||
p<n>.k<m> | erase | W | erase the key specified at position <m> from peripheral <n>'s memory |
p<n>.k<m>.blocked | 1 | R | key in memory position <m> of peripheral <n> is disabled |
W | disable key in memory position <m> of peripheral <n> | ||
0 | R | key in memory position <m> of peripheral <n> is enabled | |
W | enable key in memory position <m> of peripheral <n> | ||
p<n>.k<m>.sn | <val> | R | the serial number of the key in memory position <m> of peripheral <n> is <val>. Updated only at startup and after a call to p<n>.mem = read |
p<n>.k<m>.manager | 1 | R | the key in memory position <m> of peripheral <n> is a manager key. Updated only at startup and after a call to p<n>.mem = read |
0 | R | the key in memory position <m> of peripheral <n> is a regular key. Updated only at startup and after a call to p<n>.mem = read | |
p<n>.mem | add | W | instruct peripheral <n> to add to memory the next read key |
read | W | request to peripheral <n> the list of saved keys (see p<n>.k<m>.sn and p<n>.k<m>.manager datapoints) | |
clear | W | clear peripheral <n>'s memory | |
refresh | W | refresh peripheral <n>'s memory erasing all disabled keys | |
p<n>.mem.ok | <pos> | R | the read key has been correctly saved in memory position <pos> |
p<n>.mem.err | <pos> | R | the read key was already saved in memory position <pos> |
p<n>.mem.full | <val> | R | the memory of peripheral <n> is full and it contains <val> keys |
p<n>.mem.free | <val> | R | peripheral <n> has <val> key slots available in its memory. Updated only after a "read" request |
read | W | request the reading of available memory on peripheral <n> | |
p<n>.mem.clear | 1 | R | the memory of peripheral <n> has been cleared |
0 | R | error while clearing the memory of peripheral <n> | |
p<n>.mem.refresh | 1 | R | the memory of peripheral <n> has been refreshed |
0 | R | error while refreshing the memory of peripheral <n> | |
p<n>.alarm.forced | 1 | R | door forced alarm |
p<n>.alarm.comm | 1 | R | communication error with peripheral <n> |
0 | R | communication with peripheral <n> restored | |
p<n>.copy | <n1>:<from>:<to> | W | copy to peripheral <n>'s memory all the keys in the specified range (<from> - <to>) of peripheral <n1>'s memory. (e.g. p1.copy = 0:10:20) |
p<n>.reltime | <val> | R | the relay time of peripheral <n> is set to <val>, in sec/10 |
W | set the relay time of peripheral <n> to <val>, in sec/10 (max 65535 = 109 min) | ||
M | R | peripheral <n>'s relay is set as monostable | |
time | <val> | R | time and date set on the module, value format: "yyyy-mm-dd hh:mm:ss". Updated only after a "read" request |
W | set the module's time and date, value format: "yyyy-mm-dd hh:mm:ss" | ||
read | W | request the module's time and date |
Release Notes
3.8.0
- support for protocol versions 4.xx and 5.xx
3.7.0
- initial release
WOLF SAFETY is a registered trade mark of ELP s.n.c.