Siemens Vanderbilt Edp
Siemens / Vanderbilt is a family of security panels compatible with the control protocol EDP. This driver has been developed following the EDP protocol specification rev 2.2, 2012-11-12
The integration with HSYCO can be accomplished with a TCP/IP network connection.
Contents
Siemens / Vanderbilt Configuration
Login in the panel web configuration page using a Engineer account.
You should see something like this in the upper right corner of the web page:
Select "Configuration" then "Reporting" then "EDP". You must configure 2 different receivers, one for the command session, one for the event session.
Let's take a look in detail at the configuration of these receivers. The events receiver is configured as "Primary receiver".
Unflag "Primary receiver" for the command receiver. The "IP port" parameter must be different from the one of the event receiver. Set the "Receiver Id" to 1.
Flag "Always connected" on both the receivers. Select protocol version 2 on both. The "Receiver IP Address" is the IP address of the HSYCO server that you want to communicate with. Set the "Receiver Id" to 2.
The "Polling Time" is a very crucial parameter. In the event receiver configuration 8 seconds should be fine because every change of status is sent in asynchronous way by the panel and the polling time only represent the interval between one polling ack and the next one. In the command receiver configuration set 2 seconds, this time, by empirical methods, it's the best one to ensure the connection stability.
HSYCO Configuration
Add a SIEMENS EDP TCP I/O Server in the I/O Servers section of the Settings and set its parameters:
Communication
- IP Address: Leave empty
- IP Port: Leave empty
High Availability
- Shutdown when inactive: defaults to true.
Options
ID | Default | Values | Description |
---|---|---|---|
eventsport | 50000 | number | the TCP/IP port specified in the event receiver of the panel |
commandsport | 50001 | number | the TCP/IP port specified in the command receiver of the panel |
eventsaddress | 1 | number | the event receiver id address |
commandsaddress | 2 | number | the command receiver id address |
startupevents | true | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
gui | true | true | enable support of the tecnoalarm Web interface object |
false | disable support of the tecnoalarm Web interface object | ||
eventspolling | 8000 | number | the event receiver polling time in ms |
commandspolling | 2000 | number | the command receiver polling time in ms |