MyHome is a proprietary bus system for home automation developed by BTicino. HSYCO fully integrates with MyHome using the OpenWebNet (OWN) protocol.
HSYCO supports all MyHome devices and features that the OWN protocol officially supports, including lighting, automation, scenes, AUX and CEN addressing, the temperature control unit and burglar alarm unit.
The bus architecture can be arranged as a single bus or with a riser and several local busses.
Communication
HSYCO supports the Ethernet IP connection to MyHome through IP-based OWN gateways, including the F452, F453, F454, F453AV, MH200 and MH200N.
HSYCO also supports the L4686SDK module through an USB connection and an associated virtual serial port.
Gateway Configuration
The OWN gateway must be configured to allow open OWN connections from the IP address assigned to the HSYCO server.
L4686SDK Module
The L4686SDK interface module is connected to HSYCO using a USB cable.
The operating system creates a virtual serial port; its name depends on your HSYCO server configuration, and should be ttyUSB0 if there are no other devices connected to the USB ports.
You could also use the ftdi-n-n.n alias, that is unique for each physical USB port on the server. In this case, you should also list the full device name in the CommPortsList parameter.
L4686SDK Limitations
- L4686SDK firmware version 1.20.0 or later is required
- Not all protocol frames are supported. The I/O server has been tested with the following functions: scenarios, lights, automation, temperature control, AUX and CEN plus
- Check the L4686SDK documentation to know which functions are actually supported, also based on the L4686SDK firmware version
- The clock read and sync functions are not supported
- HSYCO only support the L4686SDK module on a single main bus; private raiser buses are not supported
- the USB connection cable should never be unplugged during normal operations. If the cable is unplugged, HSYCO will not be able to restore the connection to the L4686SDK until it is manually restarted.
HSYCO Configuration
Options
ID
|
Default
|
Values
|
Description
|
The Device Configuration Database
Datapoints
User Interface
Temperature Control Unit
UISET Actions
USER Commands
Temperature Zones
Zone unlock
Burglar Alarm Unit
UISET Actions
USER Commands
Because the MyHome burglar alarm panel cannot be directly controlled via OpenWebNet commands, there are no standard control objects for this system.
Datapoints
Gateway Module
Scenario Modules
Lighting: on/off Modules
Lighting: Dimmer Modules
Automation: Inter-locking Modules
Temperature Control: Central Unit
Temperature Control: Zones
Burglar Alarm: Main Panel
Burglar Alarm: Zones and Technical (aux)
Auxiliary Addresses
CEN Modules
CENPLUS Modules
F421 Load Control Unit
Release Notes
3.3.0
- added support of the L4686SDK interface module
3.2.2
- clock read and sync are now based on local time
3.2.1
- improved handling of connection errors
3.2.0
- new clock datapoint to read the gateway’s internal clock and set it to HSYCO's time
3.0.0