Difference between revisions of "NotifierESibM"
Line 69: | Line 69: | ||
|- | |- | ||
− | | | + | |modulesnumber |
− | | | + | |159 |
− | + | |style="white-space:nowrap"|n = 0..159 | |
− | + | |highest module address of all the connected panels. E.G. If 2 panel with 2 lines are connected and the first panel has 20 modules on the first line, and 10 on the second, and the second panel has 30 modules on the first line and 10 on the second you should set modulesnumber = 30 to read all the modules | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |style="white-space:nowrap"|n | ||
− | |the | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | |sensorsnumber |
− | | | + | |159 |
− | |style="white-space:nowrap"|n = | + | |style="white-space:nowrap"|n = 0..159 |
− | |the | + | |highest sensor address of all the connected panels. E.G. If 2 panel with 2 lines are connected and the first panel has 30 sensors on the first line, and 10 on the second, and the second panel has 50 sensors on the first line and 10 on the second you should set sensorsnumber = 50 to read all the modules |
|- | |- | ||
|zonesnumber | |zonesnumber | ||
− | | | + | |10 |
− | |style="white-space:nowrap"|n = | + | |style="white-space:nowrap"|n = 0..2000 |
− | |the number | + | |set to the highest zone number configured in the system. |
|- | |- | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|} | |} |
Revision as of 11:28, 25 March 2024
Notifier E-SIB-M is a license key to enable Modbus TCP communication for a series of Notifier and Honeywell fire detection panels:
AM8200 Notifier (legacy up to 8 lines per control panel) AM8100 Notifier AM1000CL AM2000CL AM6000CL MA1000-03 MA2000-03 MA1000-01 MA2000-01 MA1000-02 MA2000-02 AM8200N Notifier (up to 4 lines per control panel) AM8200N Honeywell (up to 4 lines per control panel) AM8200 Honeywell (legacy up to 8 lines per control panel) AM8100 Honeywell MA1000-04 MA2000-04
The integration with HSYCO can be accomplished via a standard Modbus TCP/IP connection. This I/O server was developed following the MODBUS documentation Mod-Bus_Prot_rev.01.
For any information regarding the activation of the Modbus protocol on the E-SIB-M dongle, please contact your Notifier distributor.
Communication
Notifier E-SIB-M compatible panels can be connected via ethernet. A valid IP address must be assigned to the panel. MODBUS PROTOCOL must be enabled. Please refer to the panel manual for detailed instruction about MODBUS protocol configuration.
HSYCO Configuration
Add a Notifieresibm I/O Server in the I/O Servers section of the Settings and set its parameters:
Communication
- Address: IP address of the Notifier E-SIB-M panel panel
- Port: TCP/IP port for MODBUS communication (default 502)
High Availability
- Shutdown when inactive: defaults to false.
Options
ID | Default | Values | Description |
---|---|---|---|
gui | true | true | enable support for the UI object, UISET actions and USER commands |
false | disable UI support | ||
startupevents | false | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
modulesnumber | 159 | n = 0..159 | highest module address of all the connected panels. E.G. If 2 panel with 2 lines are connected and the first panel has 20 modules on the first line, and 10 on the second, and the second panel has 30 modules on the first line and 10 on the second you should set modulesnumber = 30 to read all the modules |
sensorsnumber | 159 | n = 0..159 | highest sensor address of all the connected panels. E.G. If 2 panel with 2 lines are connected and the first panel has 30 sensors on the first line, and 10 on the second, and the second panel has 50 sensors on the first line and 10 on the second you should set sensorsnumber = 50 to read all the modules |
zonesnumber | 10 | n = 0..2000 | set to the highest zone number configured in the system. |