Difference between revisions of "XGenConnect"
Jump to navigation
Jump to search
Line 74: | Line 74: | ||
|} | |} | ||
+ | |||
+ | |||
+ | |||
+ | == Log Files == | ||
+ | If a XGenConnect I/O Server is connected to HSYCO, the security.log file will be written in the same directories as the daily log files. | ||
+ | |||
+ | This file is never overwritten or deleted from HSYCO SERVER. | ||
+ | |||
+ | <pre> | ||
+ | 2021.03.31 11:27:06.504 - xgen - HSYCO ONLINE | ||
+ | 2021.03.31 11:28:23.954 - xgen - Attiva modalità parziale** Area 1 User 1 Ora: 11:28:23 Data: 31 Mar 2021 | ||
+ | 2021.03.31 11:28:23.989 - xgen - Allarme* Area 1 Ora: 11:28:23 Data: 31 Mar 2021 | ||
+ | 2021.03.31 11:28:25.733 - xgen - Chiusura recente* Area 1 User 1 Ora: 11:28:23 Data: 31 Mar 2021 | ||
+ | 2021.03.31 11:28:25.751 - xgen - Allarme* Porta ingresso Area 1 Ora: 11:28:23 Data: 31 Mar 2021 | ||
+ | 2021.03.31 11:29:23.749 - xgen - Ripristino allarme* Porta ingresso Area 1 Ora: 11:29:23 Data: 31 Mar 2021 | ||
+ | 2021.03.31 11:29:23.772 - xgen - Disattiva modalità parziale** Area 1 User 1 Ora: 11:29:23 Data: 31 Mar 2021 | ||
+ | </pre> | ||
+ | |||
+ | Other information about the TLABQ driver are stored in the message.log daily file. | ||
+ | |||
+ | == Release Notes == | ||
+ | |||
+ | === 3.8.0 === | ||
+ | *initial release | ||
+ | |||
+ | ---- | ||
+ | |||
+ | |||
+ | ''Hesa is a registered trademarks of Hesa S.p.A.'' |
Revision as of 14:47, 31 March 2021
The xGen Connect is a multi area anti-intrusion system.
Contents
Communication
- IP Address: host name or IP address of the panel
- IP Port: TCP/IP port assigned to the panel's web server
Authentication
- User: username to access the web server
- Password: password to access the web server
Options
ID | Default | Values | Description |
---|---|---|---|
startupevents | false | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
gui | true | true | enable the UISET "visible" field for all system zones |
false | disable the UISET "visible" field for all system zones | ||
pollinterval | 1000 | n > 1000 | the data acquisition interval, in milliseconds |
logsize | 300 | n ≥ 0 | the number of log lines to display in the UI object |
Datapoints
ID | Value | R/W | Description |
---|---|---|---|
connection | online | R | connection established |
offline | R | HSYCO can't connect to the panel |
Log Files
If a XGenConnect I/O Server is connected to HSYCO, the security.log file will be written in the same directories as the daily log files.
This file is never overwritten or deleted from HSYCO SERVER.
2021.03.31 11:27:06.504 - xgen - HSYCO ONLINE 2021.03.31 11:28:23.954 - xgen - Attiva modalità parziale** Area 1 User 1 Ora: 11:28:23 Data: 31 Mar 2021 2021.03.31 11:28:23.989 - xgen - Allarme* Area 1 Ora: 11:28:23 Data: 31 Mar 2021 2021.03.31 11:28:25.733 - xgen - Chiusura recente* Area 1 User 1 Ora: 11:28:23 Data: 31 Mar 2021 2021.03.31 11:28:25.751 - xgen - Allarme* Porta ingresso Area 1 Ora: 11:28:23 Data: 31 Mar 2021 2021.03.31 11:29:23.749 - xgen - Ripristino allarme* Porta ingresso Area 1 Ora: 11:29:23 Data: 31 Mar 2021 2021.03.31 11:29:23.772 - xgen - Disattiva modalità parziale** Area 1 User 1 Ora: 11:29:23 Data: 31 Mar 2021
Other information about the TLABQ driver are stored in the message.log daily file.
Release Notes
3.8.0
- initial release
Hesa is a registered trademarks of Hesa S.p.A.