SIGFOX
Sigfox is a global network operator founded that builds wireless networks to connect low-power objects such as electricity meters and smartwatches, which need to be continuously on and emitting small amounts of data. This driver allows you to communicate with Sigfox Cloud in order to retrieve messages and status updates collected from devices. As reported in the Sigfox backend, each device is grouped into a device type.
Contents
HSYCO Configuration
Add the SIGFOX I/O Server in the I/O Servers section of the Settings and set its parameters:
Authentication
- User: optional API username
- Password: optional API password
Devices list file
At the first run of SIGFOX driver a file named "sigfox-devices_<I/O_Server_name>.ini" will be created . This file can contain a series of line, each line represents informations of a single device and can have the following format:
<device_id>:name=<device_name>,model=<device_model>
<device_id>:model=<device_model>,name=<device_name>
<device_id>:name=<device_name>
<device_id>:model=<device_model>
<device_id>
E.g.
BE1234:name=homesensor,model=eccoswitch
BE1234:model=eccoswitch,name=homesensor
BE1234:name=homesensor
BE1234:model=eccoswitch
BE1234
Device id must be present in each line while name and model are optional. Device identifiers are considered as case insensitive by the SIGFOX I/O Server, so there can't be two identifiers with the same sequence of characters in upper/lower case, e.g. "BE1234" and "be1234" are considered the same.
Options
ID | Default | Values | Description |
---|---|---|---|
startupevents | true | true | generate IO events also during the driver’s start-up phase |
false | start generating events only after HSYCO is aligned with the current status of the system | ||
acceptunknown | false | true | accept incoming messages from devices whose id isn't specified in sigfox-devices.ini |
false | doesn't accept incoming messages from devices whose id isn't specified in sigfox-devices.ini | ||
callbackport | <portNumber> | internal port used to receive incoming callback messages from Sigfox Cloud | |
callbackkey | <text> | key used in Sigfox URL callbacks to receive incoming callback messages | |
pollinterval | 30000 | 1000<n<30000 | interval (in milliseconds) between two consecutive HTTP calls at Sigfox Cloud (only for API) |
Device Messages
To retrieve device messages from Sigfox Cloud you can use API and/or callbacks. API are easier to set up but they require to wait for an interval to expire (max 30 seconds) to get every new message sent by devices to Sigfox Cloud. Callbacks are a little bit tricky to set up but they allow to retrieve every new message sent by devices as soon as Sigfox Cloud receives it.
API
In order to use Sigfox API you have to create an API user in Sigfox backend (unless you already have an existing one), then use the newly API user credentials to set User and Password in SIGFOX I/O Server configuration
Callbacks
In order to use Sigfox callbacks services you must have a public IP address and you need to set up your router ports to let outside traffic to get into your network. Every time Sigfox Cloud receive a message from a device it immediately propagates it to your SIGFOX driver, filling all message informations into an URL. Callback messages must be configured in Sigfox backend (you can set up callbacks for every device type) choosing channel "URL" and composing the URL in the following format:
http://<hsyco_ip_address>:<callbackport>/hsyco/sigfox/<I/O_server_name>?key=<callbackkey>&id={device}&field1={var1}&field2={var2}&field3={var3}...
<callbackport> and <callbackkey> must be set in SIGFOX I/O Server options. The URL fields "field1", "field2", "field3", etc.. are optionals and can be set accordingly to the type of callback you are configuring in Sigfox backend; fields order is irrelevant. URL fields must be separated with '&' character,
E.g.
http://93.45.12.54:7777/hsyco/sigfox/sgfx?key=Abc1234&id={BE1234}&time={time}&data={data}&seqNumber={seqNumber}
Below are reported all URL fields that SIGFOX driver can process:
ID | Description |
---|---|
time | timestamp (in Epoch time) of the message |
data | message content |
seqNumber | sequential number of the message |
batt | device battery voltage |
temp | device temperature (C˚) |
lqi | link quality indicator (as reported in Datapoints section) |
deviceTypeId | the ID of the device type in which this device is grouped |
Device Models
You can assign a model to each of your devices by modifying directly the file "sigfox-devices_<I/O_Server_name>.ini" (as described above) or using the SIGFOX Utility. Assigning a model to a device let the SIGFOX driver decode raw messages coming from that device accordingly to its communication protocol, this will generate more informations and relatives datapoints.
Actually the only device model supported by SIGFOX driver is the sequent:
ID | Protocol |
---|---|
eccoswitch | Ecco Switch protocol firmware V2 |
SIGFOX Utility
Use the SIGFOX Utility to automatically discover new devices or configure existing ones.
Datapoints
ID | Value | R/W | Description |
---|---|---|---|
connection | online | R | the driver is ready to accept incoming messages from Sigfox Cloud |
offline | R | initialization of the driver failed or loop cycle failed | |
devicetype.<devicetypeId>.name | <text> | R | the name of the device type corresponding to devicetypeId (only obtainable with API) |
device.<deviceId>.devicetype | <text> | R | the ID of the device type in which deviceId is grouped |
device.<deviceId>.name | <text> | R | the name of deviceId (only obtainable with API) |
device.<deviceId>.lastseen | <ts> | R | timestamp (in Epoch time) of the last message sent by deviceId |
device.<deviceId>.msg | <text> | R | last message sent by deviceId (Hexadecimal format) |
device.<deviceId>.token.end | <ts> | R | deviceId token end date (in Epoch time) (only obtainable with API) |
device.<deviceId>.lqi | 0 | R | link quality indicator (computed from the last message received by Sigfox Cloud). 0=limit, 1=average, 2=good, 3=excellent, 4=not available |
1 | R | ||
2 | R | ||
3 | R | ||
4 | R | ||
device.<deviceId>.batt.tx | <val> | R | battery voltage (during transmission) of deviceId |
device.<deviceId>.batt.idle | <val> | R | battery voltage (in idle state) of deviceId |
device.<deviceId>.temp | <val> | R | internal temperature (C˚) of deviceId |
eccoswitch
Below are reported all datapoints generated from incoming messages from eccoswitch model devices. Those datapoints are in addition to SIGFOX I/O Server standard datapoints
ID | Value | R/W | Description |
---|---|---|---|
device.<deviceId>.msg.test | 1 | R | status change on button "test" of deviceId |
0 | R | no status change on button "test" of deviceId | |
device.<deviceId>.msg.in.<n> | 1 | R | status change on input <n> of deviceId |
0 | R | no status change on input <n> of deviceId | |
device.<deviceId>.batt.idle | <val> | R | Voltage of device battery (in idle state) |
Release Notes
3.8.0
- initial release